Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting To Power Supply - Stihl RE 361 Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
English
Connect spray attachment
N
Switch on the machine with the
N
spray gun open
Actuate the spray gun several times
N
briefly in order to bleed the air out of
the machine as quickly as possible
38

Connecting to Power Supply

The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA for 30 ms.
The power connection must correspond
to IEC 60364-1 and relevant national
regulations.
When the machine is switched on,
voltage fluctuations that occur under
unfavorable mains conditions (high
power line impedance) may negatively
affect other connected electrical
appliances. Trouble is not anticipated at
power line impedances less than
0.15 ohms.
The extension cord must have the
following minimum cross-section
depending on the mains voltage and
cord length.
RE 361, RE 361 PLUS, RE 461, RE 461 PLUS, RE 471 PLUS
Cord length
Minimum cross-
section
400 V / 3~:
up to 20 m
1.5 mm
20 m to 50 m
2.5 mm
230 V 3~:
up to 20 m
2.5 mm
2
20 m to 50 m
4 mm
200 V / 3~:
up to 10 m
3.5 mm
10 m to 30 m
5.5 mm
Connection to the power supply socket
Before connection to the power supply,
check that the machine is switched off –
see "Switching off the machine"
Plug the power cord or extension
N
cord into a properly installed outlet
2