Installing your hob in complete safety
Always ensure that the air vents beneath the hob are kept clear.
Your induction hob must always be adequately ventilated.
Above a cupboard or drawer unit
4 cm mini
Gap
Ensure that the unit crossbar does not block the air
passage, make a bevel if necessary.
In case the worktop thickness is >40 mm make sure there is
enough ventilation space (5-10 mm) betwen the front of the
induction hob and the worktop.
If the appliance underneath your hob produces excess heat :
this will be detected by a safety device incorporated into your induction hob. A high temperature will be indicated by a
series of dashes or F7 will appear in the display.
If this happens we suggest you either create an opening in the side of the unit and/or install an insulation kit which will
protect your hob from the heat generated beneath it.
Opening in the side of the
unit approx 8 cm x 5 cm
Providing the advice on ventilation given above is followed, your hob can be installed above any piece of kitchen
equipment.
Above an oven
mini 5 cm
Insulation kit
Kit d'isolation (SAV)
38
MINI 4 mm
MINI 50 cm
mini 4 mm
2