10.

Technical Data

10.1.

Mo Duo

Flue outlet
Suppy air
Air distribution module
Nominal thermal output (NWL)
Partial-load thermal output
Space heating capacity
Efficiency
CO content at NWL
Flue gas temperature at NWL
Flue gas temperature at TL (partial load)
Flue gas mass flow rate at NWL
Flue gas mass flow rate at TL (partial load)
Minimum delivery pressure
Capacity of Pellet container
Min./max pellet consumption
Min./max autonomy
Air connector Ø
Flue connector Ø
Electr. power input at switch-on
Electrical power input in operation
Voltage/current frequency
Dimensions
Weight
Minimum distance
Temperature limits
Relative humidity
28
www.austroflamm.com
28
H x W x D
at the sides
(firebox)
at the sides
(Pellet container)
at the rear
at the front
EN
english
9,4 kW
2,8 kW
114 – 255 m³
90 %
<250 mg/Nm³
219 °C
94°C
5,6 g/s
3,8 g/s
12 Pa
ca. 34 kg / 51 l
0,6 – 1,87 kg/h
ca. 18 – 56 h
125 mm
130 mm
325 W
16,5 W
230 V / 50 Hz
1147 x 863 x 490 mm
274 kg
130 mm
100 mm
170 mm
1100 mm
0 – 40 °C
Non-condensing