5. Warnings and error messages

Alarms are displayed in yellow on the control panel. The pellet stove can continue to be used when an alarm is
indicated. Alarms are displayed in red. The pellet stove is inoperable when an error is displayed.
Warning code,
Error code
Fuel fill level low
Alarm - A001
Alarm - A002
Flue gas temperature
Alarm - A003
Weak battery
Alarm - A004
Error- E002
communication error
Communication error
Error- E004
Failed ignition
Error- E101
Negative pressure too
Error- E102
Firebox sensor
Error- E107
Safety switch I01
Error- E108
Safety switch I02
Error- E109
Defective room tem-
Error- E110
perature sensor
Excessive flue gas
Error- E113
Firebox temperature
Error- E114
System shut down
Error- E115
5.1.

Resetting warnings and errors

17
Description
Service due
Flue gas temperature too high; service technician required.
Replace the storage battery (CR2032) of the control unit.
The battery must be replaced every 2 years as part of the
IR
Communication error between the control unit and the display;
1. The automatic start process was terminated manually.
2. Supply air pipe, burner pot, flue gas outlets, flue gas fan or
low
or too high
error
Caution: STB can only be reset after cooling below 105°C.
error
Room temperature sensor defective. Replace sensor.
temperature
too low
Solution
Refill pellets;
reset the fill level indicator to "FULL".
.
Maintenance by a service technician is necessary.
service.
Infrared sensor malfunction;
contact service technician.
check data cable plug connections.
Restart.
Possible causes:
flue pipe clogged.
3. Chimney stack dirty.
4. Chimney draught too strong.
Firebox temperature sensor cable defective;
call customer service.
RESET the safety temperature limiter (STB)!
1. Pellet hopper lid is open.
2. Riddling grate not closed.
3. Jumper on IO2 not correctly plugged in.
If the fault persists, contact the service technician.
Contact service technician.
Chimney fan and flue gas ducts are clogged;
cleaning is required.
Possible causes:
1. Failed ignition.
(Empty the burner pot and restart the appliance).
2. The hopper is empty (refill the fuel hopper).
3. DC side of the control unit must be earthed.
((The furnace body has generated millivolts).
Software must be reloaded.
Contact a service technician.