Herunterladen Inhalt Inhalt Diese Seite drucken

Adjust Material Flow [4-1], [4-2], [4-3] Und [4-4] - Material Flow Control Fully Opened - SATA SATAjet 5000 B Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SATAjet 5000 B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Operating instructions SATAjet 5000 B RP/HVLP
7.1. Adjust spray gun inlet pressure
• Pull the trigger fully and adjust the spray gun inlet pressure (see chap-
ter 2) following instructions of one of the following sections ([3-1],
[3-2], [3-3], [3-4] and [3-5]), then release the trigger.
• With [3-3], [3-4] and [3-5], the air micrometer [1-13] must be fully
opened/in vertical position.
• If the required spray gun inlet pressure is not reached, the pressure
at the compressed air circuit has to be increased; too high pressure
results in too high trigger forces.
[3-1] SATA adam 2 (accessory / accurate method).
[3-2] Separate gauge with control device (accessory).
[3-3] Separate gauge without control device (accessory).
[3-4] Pressure regulation at the compressed air circuit (most inaccu-
rate method).
7.2. Adjust material flow
rial flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjust spray fan pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.
Notice!
[4-1], [4-2], [4-3] und [4-4] - mate-
Notice!
EN
105

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis