10. Cleaning and Maintenance

ATTENTION!
Unplug the power plug from the electri-
cal outlet before starting any work on
the power tool.
Cleaning
• Keep the air vents of the machine clean
in order to prevent overheating.
• Clean the machine's casing regularly with
a soft cloth, preferably after each use.
• Keep the air vents free from dust and dirt.
• If the dirt cannot be removed easily, use a
cloth that is moistened with soapy water.
ATTENTION!
Do not use solvents such as benzene,
alcohol, ammonia solutions, etc. These
solvents may damage the plastic parts.
Service information
Please note that the following parts of this
product are subject to normal or natural wear
and tear, and are therefore also required as
consumables.
Wear parts*: Carbon brush, mixing rod
* Not necessarily included in the scope of
delivery!

11. Storage

• The whole machine and all accessories
must be thoroughly cleaned.
• Store devices and accessories out of the
reach of children in a dark and dry place
above freezing point. The optimum stor-
age temperature lies between 5 and 30
°C. Store the power tool in its original
packaging.
• Do not wrap the machine into bags or cov-
ers made of nylon or plastic, as dampness
may develop.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58

12. Electrical connection

m The electric motor installed is connected
and ready for operation.
The connection complies with the applicable
VDE and DIN provisions.
The customer's mains power connection
as well as the extension lead used must
also comply with these regulations and
the local electricity supplier regulations.
Damaged electrical connection cables
The insulation on electrical connection ca-
bles is often damaged.
Possible causes:
• Pressure points, where connection cables
are passed through windows or doors.
• Kinks where the connection cable has
been improperly fastened or routed.
• Places where the connection cables have
been cut due to being driven over.
• Insulation damage due to being ripped out
of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables
must not be used and are life-threatening
due to the insulation damage.
Check the electrical connection cables for
damage regularly. Ensure that the connec-
tion cables are disconnected from electrical
power when checking for damage. Electrical
connection cables must comply with the ap-
plicable VDE and DIN provisions, and the
local power supply regulations. Only use
connection cables marked with H07RN. The
printing of the type designation on the con-
nection cable is mandatory.
AC motor
• The mains voltage must be 220÷240 V/50
Hz.
• Extension leads up to 25 m long must
have a minimum cross section of 1.5 mm²,
and over 25 m long must have a minimum
cross section of 2.5 mm².
• The mains connection must be protected
with a max. 16 A fuse.