Installation location and position
General
Please note the following criteria when choosing a location for the Ohmpilot:
comments regar-
ding choice of
Install only on a solid surface.
location
If the Ohmpilot is installed in an enclosed space, then forced-air ventilation must be
provided to ensure adequate heat dissipation.
IMPORTANT! The maximum cable length from the output of the Ohmpilot to the load
(heating element) must not exceed 5 m.
Choice of loca-
tion
The Ohmpilot is suitable for installation indoors.
Do not install the Ohmpilot outdoors.
The Ohmpilot corresponds to protection class IP 54 and is protected
against spray water from all sides.
In order to minimise the heating up of the Ohmpilot, do not expose it
to direct insolation. Mount the Ohmpilot in a protected position. The
Ohmpilot must only be mounted and operated at an ambient tempera-
ture of 0-40 °C.
IMPORTANT! The Ohmpilot must not be installed or used at altitudes
above 2000 m.
Max. ambient temperatures:
0 °C / +40 °C
Relative humidity:
0 - 99%
The airflow within the Ohmpilot is from
the bottom to the top.
77