Annex
Scope of delivery of the b-control units
b-control deluxe
› display
› power module
› power cord
› display connecting cable
› temperature sensor
› fan
Assembly of the control units
The following describes the installation and connecting steps of the b-control units. Please also note the attached assembly instruction.
1. Lay the cable for the front heater in the floor, the ends of the cables including their plug pins and the grey bow (= connection to the
control unit FRONT/BACK) have to point to the control box and to the power module. These plugs will be plugged into the power module
(control box). This handling ensures that the ends of the cables are connected correctly to the accurate socket of the front heater. (Please
double check!) The cable of the front heater is marked with a red dot. This marked cable spot will be connected to the plug.
2. The power module (control box) will be attached to the backside of the inspection board above the already prepared boreholes using
the provided screws (except for the model face-2-face: attached at the backside of the cabin).
3. Plug the fan connection cable into the intended plug socket.
4. Connect the plugs of the LED light bar, the diffused light and the speakers into the intended plug sockets.
5. To enable the use of the audio input in the control unit (available for option "for all senses"), the 3.5 mm jack socket on the back of the
control unit must be connected to the AUX input of the control box using the enclosed cable.
6. Connect the temperature sensor cable into the intended socket.
7. Connect the plugs for the cabin floor heating (available for option „warm feet") on the base plate and link the connection to the control
box using the intended plug.
8. Connect the control box and the power module using the enclosed cable.
9. Plug the enclosed network cable into the power module.
10. Check the firm location of all connectors.
11. Plug the power plug into a verified shockproof socket.
Possible error causes
The control unit cannot be turned on:
 Is there a supply voltage? Check your circuit breaker.
 Has the power lead been unplugged? Plug in the power lead.
 The power lead from the power module to the control panel is not plugged in properly.
Control can be turned on, heaters do not warm up, temperature on the display > 140 °C (temperature sensor only included for b-control deluxe):
 Temperature sensor defective or not plugged in.
Control can be turned on; cabin temperature is displayed correctly but heaters do not warm up:
 Is the heater power set to 0? Adjust performance via touch control panel.
 Is the heater bulb faulty? Contact the b-intense
In case you cannot solve the problem, please contact your b-intense
b-control basic / b-control single
› display
› power module
› power cord
› display connecting cable
service engineer.
®