Transportation and storage

Transportation of the b-intense
The b-intense
infrared cabin must be transported on pallets by a transport company suitable for pallet transport and fragile goods. In case
®
of visible damage to the packaging, please contact the b-intense
Storage of the b-intense
The storage of the b-intense
®
b-intense
®
quality check quickly. The stored product must remain on the pallet until the final installation.
Placement of the b-intense
After the assembly (see specific applicable b-intense
3 meter long connection cable. The best location is close to a socket, which will also be easily accessible after the assembly of the cabin. Ensure
that there are no tripping hazards near the b-intense
Please consider the following recommendations for installation and storage:
› The cabin must be stored and installed indoors.
› The ambient temperature of the b-intense
› The optimal humidity should not exceed 60%. If this is not possible, suitable ventilation of the space to be used must be arranged.
› The cabin must be protected from any direct water spray and from wet or damp from the floor. Condensation in the room where the cabin
is sited must be prevented and adequate ventilation must be ensured.
› Ensure that the floor surface for the cabin is flat and level, although minor irregularities in the surface can be offset by the adjustable feet
fixed to the underside of the cabin base.
› A gap of at least 2 cm between the wall and the cabin has to be considered.
› The distance from the cabin roof to the ceiling above should be at least 10 cm.
Please observe the following safety-relevant parameters:
› The horizontal minimum distance of the back-heater to burning materials is 10 cm.
› The horizontal minimum distance of the front-heater to burning materials is 30 cm.
› The heaters must not be covered.
› The power circuit must be secured using a fault-current circuit breaker (FI) with a trip current of 30mA.
infrared cabin
®
infrared cabin
®
infrared cabin should be as short as possible and not exceed one month in order to be able to complete the
infrared cabin
®
assembly instructions), the b-intense
®
®
infrared cabin.
®
infrared cabin should be at least 18° C (room temperature) and at maximum 35° C.
office immediately. The cabin must not be assembled until release.
®
infrared cabin is ready to be plugged in with a
®