Umwelt/EMV
EMV ..................................................................................IEC 61326-2-4
Umgebungstemperaturen:
Betrieb .............................................................................. -40...+70 °C
Transport .......................................................................... -50...+85 °C
Lagerung........................................................................... -55...+80 °C
Klimaklassen nach IEC 60721:
Ortsfester Einsatz (IEC 60721-3-3) .................................................. 3K24
Transport (IEC 60721-3-2) .............................................................. 2K11
Langzeitlagerung (IEC 60721-3-1) .................................................. 1K23
Mechanische Beanspruchung nach IEC 60721:
Ortsfester Einsatz (IEC 60721-3-3) ................................................. 3M12
Transport (IEC 60721-3-2) ............................................................... 2M4
Langzeitlagerung (IEC 60721-3-1) ................................................. 1M12
Anschluss
Anschlussart ............................................... Schraub- oder Federklemme
Schraubklemmen:
Nennstrom ................................................................................... ≤ 10 A
Anzugsmoment ............................................0,5...0,6 Nm (5...7 lb-in)
Querschnitt ....................................................................... AWG 24...12
Abisolierlänge ................................................................................8 mm
Starr/flexibel ....................................................................0,2...2,5 mm
Flexibel mit Aderendhülse mit/ohne Kunststoffhülse ........................
.......................................................................................0,25...2,5 mm
Mehrleiter starr ................................................................0,2...1,5 mm
Mehrleiter flexibel ...........................................................0,2...1,5 mm
Mehrleiter flexibel mit Aderendhülse ohne Kunststoffhülse ..............
.......................................................................................0,25...1,5 mm
Mehrleiter flexibel mit TWIN Aderendhülse mit Kunstoffhülse ..........
.......................................................................................0,25...1,5 mm
Federklemmen:
Nennstrom ................................................................................... ≤ 10 A
Querschnitt ....................................................................... AWG 24...14
Abisolierlänge ..............................................................................10 mm
Starr .................................................................................0,2...2,5 mm
Flexibel mit Aderendhülse .............................................0,75...2,5 mm
Flexibel mit Aderendhülse mit/ohne Kunststoffhülse ........................
.......................................................................................0,25...2,5 mm
Mehrleiter flexibel mit TWIN Aderendhülse mit Kunstoffhülse ..........
.........................................................................................0,5...1,5 mm
Öffnungskraft ...................................................................................50 N
Testöffnung, Durchmesser ..........................................................2,1 mm
Anschlussart .............................................. Klemmen Up, AK1, GND, AK2
Einzelleitungen für Klemmen Up, AK1, GND, AK2:
Leitungslängen .......................................................................... ≤ 0,5 m
Anschlussvermögen .............................................................≥ 0,75 mm
Environment/EMC
EMC ...................................................................................IEC 61326-2-4
Ambient temperatures:
Operation .......................................................................... -40...+70 °C
Transport .......................................................................... -50...+85 °C
Storage ............................................................................. -55...+80 °C
Classification of climatic conditions acc. to IEC 60721
Stationary use (IEC 60721-3-3) ....................................................... 3K24
Transport (IEC 60721-3-2) .............................................................. 2K11
Long-term storage (IEC 60721-3-1) ................................................ 1K23
Classification of mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ...................................................... 3M12
Transport (IEC 60721-3-2) ............................................................... 2M4
Long-term storage (IEC 60721-3-1) ............................................... 1M12
Connection
Connection type .....................................screw-type/push-wire terminal
Screw-type terminals:
Nominal current ........................................................................... ≤ 10 A
Tightening torque .........................................0.5...0.6 Nm (5...7 lb-in)
Cross section ..................................................................... AWG 24...12
Stripping length .............................................................................8 mm
Rigid/flexible ...................................................................0.2...2.5 mm
2
Flexible with ferrules with/without plastic sleeve .............................
.......................................................................................0.25...2.5 mm
2
2
Multi-conductor rigid .......................................................0.2...1.5 mm
Multi-conductor flexible ..................................................0.2...1.5 mm
2
Multi-conductor flexible with ferrules without plastic sleeve ............
.......................................................................................0.25...1.5 mm
2
Multi-conductor flexible with TWIN ferrules with plastic sleeve ........
.......................................................................................0.25...1.5 mm
2
Push-wire terminals:
Nominal current ........................................................................... ≤ 10 A
Cross section ..................................................................... AWG 24...14
Stripping length ...........................................................................10 mm
Rigid ................................................................................0.2...2.5 mm
2
2
Flexible with ferrules with plastic sleeve .......................0.75...2.5 mm
Flexible with ferrules with/without plastic sleeve .............................
2
.......................................................................................0.25...2.5 mm
Multi-conductor flexible with TWIN ferrules with plastic sleeve ........
.........................................................................................0.5...1.5 mm
2
Opening force ..................................................................................50 N
Test opening, diameter ...............................................................2.1 mm
Connection type .........................................terminals Up, AK1, GND, AK2
Single cables for terminals Up, AK1, GND, AK2:
Cable lengths ............................................................................. ≤ 0.5 m
Connection properties ..........................................................≥ 0.75 mm
2
isoMIL425HV_D00204_05_Q_DEEN / 02.2021
2
2
2
2
2
2
2
2
2
2
2