6.2. Voltage measurements
WARNING! To avoid possible electric shock, instrument damage and/or equipment damage, do not
attempt to take any voltage measurements if the voltage is above 1000 V AC/DC are the maximum
voltages that this instrument is designed to measure. The "COM" terminal potential should not exceed
1000 V measured to ground.
1. Select mV or V-function with the rotary function-switch.
2. Select the desired AC voltage range or DC voltage range, by pressing MODE-button.
3. Slide socket lock upwards and connect the black test lead to the COM input of the device.
4. Plug the red test lead into the V//CAP/
a voltage measurement is required. Voltage is always measured in parallel across a test point.
Turn on power the circuit/device to be measured and make the voltage measurement reduce the
range setting if set too high until a satisfactory reading is obtained.
6. After completing the measurement, turn off power to the circuit/device under test, discharge all
capacitors and disconnect the meter test leads.
Understanding Phantom readings
In some DC and AC voltage ranges, when the test leads are not connected to any circuit, the display
might show a phantom reading. This is normal. The meter´s high input sensitivity produces a
wandering effect. When you connect the test leads to a circuit, accurate reading appears.
Warning!
If the test leads are applied to an electrical outlet do not set under all circumstances the Function /
Range switch to a different range. This could damage the internal circuitry of the device and serious
injury.
/Hz - input of the device and connect the circuit where