Herunterladen Diese Seite drucken

PeakTech 1665 Bedienungsanleitung Seite 30

Digital-zangenmessgerät
Vorschau ausblenden Andere Handbücher für 1665:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10
MAX/MIN-button
Press the MAX/MIN button to activate the MAX/MIN recording mode. The display icon
"MAX" will appear. The meter will begins recording and displaying the maximum value
measured.
Press the MAX/MIN button and "MIN" will appear. The meter will display the minimum
value measured during the recording session.
Press the MAX/MIN button and "MAX MIN" will appear. The meter will display the
present reading, but will continue to update and store the max and min readings.
To exit MAX/MIN mode press and hold the MAX/MIN button for 2 seconds.
11
REL-button (Relative measurement)
In the relative mode the value shown on the LCD is always The difference between the
stored reference value and the present reading. For example, if the reference value is
24.000 V and the present reading is 12,50 V the display will indicate –11,50 V. If the new
reading is the same as the reference value, the display will be zero. This feature also is
made as DCA ZERO adjustment.
12
Hz/%-button:
This keys acts with trigger. Press "Hz/Duty" key when frequency mode is in operation,
the meter will switch to duty cycle measurement mode. Press this key again to switch to
frequency measurement mode also.
13
LCD display
4 ¾ - LCD – display with bargraph
COM – input socket
14
15
V//CAP-input socket
16
Battery compartment (rear side)
-28-