3.2.5 Adjusting the float switch cable length
For pumps supplied with a float switch, the difference
in level between start and stop can be adjusted by
changing the free cable length between the float
switch and the pump handle.
An increased free cable length will result in fewer
starts and stops and a large difference in level.
A reduced free cable length will result in more
frequent starts and stops and a small difference
in level.
The stop level must be above the pump inlet to
prevent the pump from taking in air.
L
Fig. 4
Start and stop levels
The start and stop levels vary according to the cable
length.
Unilift AP start and stop levels
Minimum cable
length (L):
100 mm
Pump
Start
type
[mm]
AP12.40
360
AP12.50
410
AP35
440
AP50
460
*
Minimum stop level during continuous operation
or when using an external controller.
8
Start
Stop
Maximum cable
length (L):
250 mm
Stop
Start
Stop*
[mm]
[mm]
[mm]
230
370
100
250
380
110
280
450
155
320
450
190

4. Electrical connection

DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before
starting any work on the product.
- Make sure that the power supply cannot
be accidentally switched on.
DANGER
Electric shock
Death or serious personal injury
- The installation must be fitted with a
residual-current device (RCD) with a
tripping current less than 30 mA.
DANGER
Electric shock
Death or serious personal injury
- Make sure that the power supply plug
delivered with the product is in
compliance with local regulations.
- The plug must have the same protective
earth (PE) connection system as the
power outlet. If not, use a suitable
adapter if allowed by local regulations.
DANGER
Electric shock
Death or serious personal injury
- Power cables without a plug must be
connected to a supply disconnecting
device incorporated in the fixed wiring
according to the local wiring rules.
All electrical connections must be carried
out by a qualified person in accordance
with local regulations.
Depending on local regulations, a pump
with minimum 10 m of mains cable must
be used if the pump is used as a portable
pump for different applications.