Whatman™ Polycap TF
Product Information sheet
Warning
For research use only.
Not recommended or intended for diagnosis of disease in humans or
animals.
Do not use internally or externally in humans or animals.
• Venting
• Gas filtration
• Solvent filtration
• Solvent resistant capsule
• Autoclavable
• PTFE membrane
Polycap TF filter devices are manufactured with
rugged PTFE membrane and polypropylene housing.
No glue, adhesives, metal, epoxy or other extraneous
materials are used in construction. All seals are fused.
This document provides general information on the
products listed. The specifications in the Technical
Data section are intended to provide the basis for
establishing functional use, as well as setting the
quality assurance test performance levels.
* Connectors vary by product number, see chart on
back
Polycap TF Features
• Hydrophobic PTFE membrane
• Autoclavable
• Flow Direction: Bi-Directional; certain
applications may require orientation, i.e., vents
• Integrity testable: Bubble Point.
• Compact: Efficient design provides high effective
filtration area in small size
• Vented: Manual vent with luer lock can function
to: bleed air from
upstream, serve as injection or sample port. Vent
is on inlet side of housing.
• Product Identification and Lot No. stamped into
each housing
• Package Clean "double wrapped"
• Manufactured in ISO controlled production
facilities
• 100% Integrity Tested during manufacture
Typical Applications for Whatman Polycap TF Filter
Capsules
Venting: Vent Filling, Mixing, Holding, Autoclave, and Fermentation
Vessels
In Line Filtration: Sterilize and Remove Particles from Air/Gas/Liquid
Streams • Remove Liquid Aerosols from Air/Gas Streams • Degas,
Clarify, and Sterilize Liquid Streams
Other Uses: Clean Nitrogen used to dry samples • Ensure clean Inert
Gases in vial filling lines • Instrument Gas/Air preparation • Point of use
"Ultra Clean" Gases, Air, Solvents for Air Guns & Cleaning Wands
Isolation (gases pass, liquids/aerosols stopped): Isolation of Gases or
Vents for Incubators, Autoclaves, Lyophilizers, EtO Sterilizers • Isolation
of Exhaust from Fermentors
Electronics: Photoresists, solvents, gases for research or industry
*
Pharmaceutical: Vents and In Line for production systems
Biotech: Vents & exhausts for biological environments, in-line gas
sterilization.
48 mm
F
Polycap
TF
TM
L
POLYCAP
(1.9 i n.)
TM
Total Polypropylene
O
housing
Operating Instructions:
W
media & supports
Safety: Considering the special factors of your application, consult
the Technical Data section on back to determine correct use. Key
*
66 mm
safety concern is not to exceed the pressure, temperature, or chemical
(2.6 in.)
compatibility recommendations.
*
PTFE membrane considerations: PTFE membrane is hydrophobic and
will not allow water (aqueous solutions) to pass without high pressure.
These pressures are called the Water Breakthrough Test (WBT) values,
and change with the pore size of the membrane. Aqueous solutions
96 mm
may be filtered if the membrane is initially "wetted" with alcohol or
(3.8 in.)
other appropriate solvents. PTFE membrane will stop aqueous aerosols
F
Polycap
TM
TF
L
POLYCAP
TM
Total Polypropylene
O
in gas streams.
housing
W
media & supports
Efficiency: To maximize filtration throughput, use the largest pore size
*
filter that will provide the required cleanliness. If the material to be
66 mm
filtered is heavily contaminated, consider prefilters. To extend filter life
(2.6 in.)
use low flow or pressure.
*
Autoclaving: Autoclave; requires 121°C at 1.05 Kg/cm² (15 psi) for
20 minutes. May tolerate 132°C for one hour. Multiple autoclave cycles
may be possible, however, reuse is the responsibility of the operator,
who should protect the device from cross contamination and detect
loss of integrity by appropriate testing. (Et0 sterilization should be
possible but no studies have been conducted. Radiation is destructive
to PTFE.)
183 mm
(7.2 in.)
Filtration Installations:
Vents: Attach one connector to vessel, the other connector is open to
the atmosphere. If exhaust gas is saturated with moisture, install vent
F
Polycap
TM
TF
filter in a vertical position to allow collected moisture to drain back into
L
POLYCAP
TM
Total Polypropylene
O
housing
W
media & supports
vessel rather than fill (and block) vent filter housing. Sterilizing vents are
typically 0.45 μm, or for longer duration and maximum security, use a
*
0.2 μm membrane.
66m m
(2.6 in.)
Air/Gas "In-Line": Effective service life varies. Replacement is required
on a timely (routine) basis. Monitor pressure build-up or flow restriction
to determine frequency. Pore size selection is based on application.
Solutions: Small volumes may be filtered using a syringe; larger
volumes may be filtered by connecting to the outlet of a pressure
vessel or "in line" using gravity, vacuum, or peristaltic pump for the
pressure required to filter. Air Locks seriously hamper flow rates; to
eliminate, point the outlet of the filter device upward during initiation of
liquid flow. The air in the system and filter device must be flushed prior
to the membrane being wetted.
Integrity Testing:
Bubble Point (BP) Test: Flush the PTFE membrane filter device with an
appropriate solution (methanol). After the membrane is completely
wetted, apply air under controlled pressure until air breaks through the
membrane and bubbles from the exit. The pressure at which air passes
through the "wetted" membrane is the "bubble point". Refer to the table
for pore size and methanol BP values. The test is best conducted with

Werbung

loading

Inhaltszusammenfassung für GE Whatman Polycap TF

  • Seite 1 GE Healthcare Typical Applications for Whatman Polycap TF Filter Capsules Life Sciences Venting: Vent Filling, Mixing, Holding, Autoclave, and Fermentation Vessels In Line Filtration: Sterilize and Remove Particles from Air/Gas/Liquid Whatman™ Polycap TF Streams • Remove Liquid Aerosols from Air/Gas Streams • Degas, Clarify, and Sterilize Liquid Streams Other Uses: Clean Nitrogen used to dry samples •...
  • Seite 2 outlet connector pointed upward. pour la taille des pores et les valeurs Methanol BP. La solution ideale consiste a pratiquer le test avec le raccord de sortie pointe vers le haut Filtration Liquid/Gas Venting Aération Instrucciones de Utilizacion: Normal Flow Ventilación Luftüng Seguridad—Consulte el cuadro de Caracteristicas Técnicas en la sección trasera de este folleto para cerciorarse de que las condiciones...
  • Seite 3 Technical Data: Polycap TF Venting & Solvent überschritten werden. Filtration PTFE-Membran: Die PTFE-Membran ist hydrophob und läßt Wasser (wässrige Lösung) nur bei Anwendung von hohen Drücken durch. Diese Chemical Resistance Summary* Drücke werden als Wasserdurchbruchtest (WBT)-Werte bezeichnet. Sie Classes of Substances Polypropylene/PTFE verändern sich mit der Porengröße der Membran.
  • Seite 4 All goods and services are sold subject to the terms and conditions Maximum Pressure: 60 psi (4.1 bar) of sale of the company within GE Healthcare which supplies them. Effective Filtration Polycap 36 – 500 cm² A copy of these terms and conditions is available on request.