Risk of fire!
Fatty deposits in the grease filter may
catch fire. The specified safety clearances
must be complied with in order to prevent
a build-up of heat. Refer to the information
provided for your cooker. If gas and
electric hobs are being operated together,
the largest specified clearance applies.
Grease deposits in the grease filter may
Risk of fire!
catch fire. Never work with naked flames
close to the appliance (e.g. flambéing). Do
not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-
removable cover is available. There must
be no flying sparks.
When conveying the exhaust air, official and
legal regulations (e.g. state building
regulations) must be followed.
Risk of death!
Risk of poisoning from flue gases that are
drawn back in. The exhaust air must not be
conveyed into a functioning smoke or
exhaust gas flue or into a shaft which is
used to ventilate installation rooms that
contain heating appliances. If the exhaust
air is to be conveyed into a non-functioning
smoke or exhaust gas flue, you must obtain
the consent of the heating engineer
responsible.
Danger of death!
Risk of poisoning from flue gases that are
drawn back in.
Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as room
air-dependent heat-producing appliance is
being operated.
Room air-dependent heat-producing
appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters
or water heaters) obtain combustion air
from the room in which they are installed
and discharge the exhaust gases into the
open air through an exhaust gas system
(e.g. a chimney).
In combination with an activated vapour
extractor hood, room air is extracted from
the kitchen and neighbouring rooms - a
partial vacuum is produced if not enough
fresh air is supplied. Toxic gases from the
chimney or the extraction shaft are sucked
back into the living space.
Adequate incoming air must therefore
always be ensured.
An incoming/exhaust air wall box alone
will not ensure compliance with the limit.
Safe operation is possible only when the
partial vacuum in the place where the heat-
producing appliance is installed does not
exceed 4 Pa (0.04 mbar). This can be
achieved when the air needed for
combustion is able to enter through
openings that cannot be sealed, for
example in doors, windows, incoming/
exhaust air wall boxes or by other technical
means.
In any case, consult your responsible
Master Chimney Sweep. He is able to
assess the house's entire ventilation setup
and will suggest the suitable ventilation
measures to you.
Unrestricted operation is possible if the
vapour extractor hood is operated
exclusively in the circulating-air mode.
Danger of death!
Risk of poisoning from flue gases that are
drawn back in. If installing a ventilation
system in a room with a heat-producing
appliance connected to a chimney/flue, the
electricity supply to the hood must be
equipped with a suitable safety switch.
Risk of injury!
Components inside the appliance may
have sharp edges. Wear protective gloves.
The appliance may fall down if it has not
Risk of injury!
been properly fastened in place. All
fastening components must be fixed firmly
and securely.
The appliance is heavy. To move the
Risk of injury!
appliance, 2 people are required. Use only
suitable tools and equipment.
Changes to the electrical or mechanical
Risk of injury!
assembly are dangerous and may lead to
malfunctions. Do not make any changes
to the electrical or mechanical assembly.
25