5

Part names and functions

 Concealed microcomputer control type (main unit)
▼ VN-M150 to 1000HE
Electrical control cover
SA
(Supply air)
Inspection cover
Model No.
indication
OA
(Outdoor air)
Heat exchange
EA
element (two)
(Exhaust air)
Heat exchange element (two)
B
EA
RA
(Exhaust
(Return
air)
air)
Indoor
Outdoor
side
side
OA
(Outdoor
air)
SA
(Supply
air)
Inspection cover
Fixing bracket
Filter (Two for each
Fixing lever
element)
Model
A
B
VN-M150HE
900
900
VN-M250HE
900
900
VN-M350HE
900
900
VN-M500HE
1140
1140
Dimensions of hanging parts are not included.
13-EN
▼ VN-M1500 and 2000HE
Filter (Two for each
element)
RA
(Return air)
1189
C
RA
(Return
air)
EA
(Exhaust
air)
Outdoor
Indoor
side
side
OA
(Outdoor
air)
SA
(Supply
air)
Fixing bracket
Inspection cover
Filter (Two for each element)
Fixing lever
C
Model
A
290
VN-M650HE
1140
290
VN-M800HE
1189
290
VN-M1000HE
1189
350
– 7 –
 Remote controller for the Air to Air Heat Exchanger NRC-01HE

◆ Operation section

• One of these remote controllers can be used to control both indoor air
conditioner units and Air to Air Heat Exchangers (up to 8 units in total).
• After setting the operation conditions, you can use the units by just pressing
the ON/OFF button.
• Functions concerning controlling the Air to Air Heat Exchanger are
explained here. For controlling an air conditioner, refer to the owner's
manuals supplied with the air conditioner.
810
1
button (Fan speed select button) (*1)
Selects the desired Fan speed.
2
button (Timer set button)
Used for timer setting
3
button (Test button)
Used for service.
Do not use this button in everyday operations.
4
button (Ventilation button)
This button is used when the Air to Air Heat
Unit: mm
Exchanger is in a system linked with air
B
C
conditioners. Push the
the Air to Air Heat Exchanger. Turning on/off the
1140
350
air conditioner also turn on/off the Air to Air Heat
1189
400
Exchanger.
1189
400
* No Air to Air Heat Exchanger is connected or
separate operation of the Air to Air Heat
Exchanger is not set, if "
remote controller display after pushing the
button.
5
button (Filter reset button)
Resets "
1 8
2
5
3
7
6
Use to initiate power saving mode.
7
SWING/FIX
button) (*1)
Use to select automatic swing or fixed louver
position.
* Not available for concealed duct, slim duct, floor
8
Operation lamp
Lights up during operation.
button to turn on/off
Blinks when an error occurs or the protective
device activates.
9
Turns on the unit when pressed, and turns it off
when pressed again.
" appears on the
10
(*1)
Selects desired operation mode.
FILTER" indication after cleaning.
Display
section
Operation
section
9
10
4
6
button (Power save operation) (*1)
button (Swing / Louver direction
concealed and floor standing cabinet fresh air
intake types.
button
button (Operation mode select button)
14-EN