System configuration

The control method of this product differs depending on the system configuration. Operate it following the methods
explained in the system configuration examples below.
• For the actual system configuration, ask your dealer or the installer of the product for information.
• Refer also to the installation manuals and owner's manuals of the remote controllers.
• If you use the central remote controller, refer also to its installation manual and owner's Manual.
System example
A. Air to Air Heat Exchanger system
Air to Air Heat
Exchanger
Remote controller for the Air to Air
Heat Exchanger NRC-01HE
Remote controller for air
conditioner
RBC-AMS41E
B. Air to Air Heat Exchanger system linked with air
conditioners
Outdoor
unit
Air
Air
Air to Air
conditioner
conditioner
Heat
Exchanger
Remote controller for air
conditioner
RBC-AMT32E, AMS41E
Remote controller for the Air to
Air Heat Exchanger
NRC-01HE
11-EN
Operation
Cautions
• Using the remote controller for
If two remote
the Air to Air Heat Exchanger
controllers are used,
NRC-01HE, you can start and
the latter operation
stop the unit, control the
overrides the former
Ventilation fan speed, and select
and their indications
the ventilation mode.
always reflect the result
of the latter operation.
* The remote controllers for the air
conditioner RBC-AMT32E are not
compatible with the Air to Air Heat
Exchanger system. Only ON/OFF
operation is available for RBC-
AMS41E.
For operation details using the
remote controller for the Air to Air
Heat Exchanger NRC-01HE, see
page 10 "6.How to use".
• The remote controller for the air
If two remote
conditioner or the Air to Air Heat
controllers are used,
Exchanger can be used to start /
the latter operation
stop the whole system.
overrides the former
and their indications
• The remote controller for the air
always reflect the result
conditioner or the Air to Air Heat
of the latter operation.
Exchanger can be used to start /
stop the Air to Air Heat
Exchanger separately.
* However, setting modifications are
Air to Air
required for separate control.
Heat
Contact your dealer for more
Exchanger
information.
• The remote controller for the Air
to Air Heat Exchanger NRC-
01HE can be used to control the
Ventilation fan speed and
ventilation mode of the Air to Air
Heat Exchanger.
• The remote controller for air
conditioner RBC-AMT32E,
AMS41E cannot be used to
control the Ventilation fan speed
or ventilation mode of the Air to
Air Heat Exchanger.
For operation details using the
remote controller for the Air to Air
Heat Exchanger NRC-01HE, see
page 10 "6.How to use".
System example
C. Central control system
(When controlling the air conditioner group and the Air to Air
Heat Exchanger group separately)
Outdoor
Central controller for 64/
unit
128 units / groups
TCB-SC642TLE2
BMS-CM1280TLE
Air
Air to Air
Air
conditioner
conditioner
Heat
Exchanger
Remote controller for the Air
Remote controller for air
to Air Heat Exchanger
conditioner
NRC-01HE
RBC-AMT32E, AMS41E
Remote controller for air
conditioner
RBC-AMS41E
D. Central control system
(When controlling the air conditioners and the Air to Air Heat
Exchangers together)
Outdoor
Central controller for 64/
unit
128 units / groups
TCB-SC642TLE2
BMS-CM1280TLE
Air
Air
Air to Air
conditioner
Heat
conditioner
Exchanger
Remote controller for the Air to Air
Heat Exchanger
NRC-01HE
Remote controller for air conditioner
RBC-AMT32E, AMS41E
NOTE
The heat exchange element may smell during the initial period of use. However, this is not a malfunction and the smell
is harmless.
– 6 –
Operation
Cautions
• The central controller can be
If three control devices
used to start / stop the whole
are used; the central
system and separately start /
controller and the
stop groups of air conditioners
remote controllers for
and the Air to Air Heat
the Air to Air Heat
Exchangers. (In this system, the
Exchanger and the air
air conditioners and the Air to Air
conditioner, the latter
Heat Exchangers are not linked
operation overrides the
in operation.)
former regardless of
which device is used.
• The central controller cannot be
used to control the Ventilation
fan speed or ventilation mode of
the Air to Air Heat Exchanger.
Air to Air
• If the remote controller for the Air
Heat
to Air Heat Exchanger NRC-
Exchanger
01HE has been installed, you
can start and stop the unit,
control the Ventilation fan speed,
and select the ventilation mode
with the remote controller.
* The remote controllers for the air
conditioner RBC-AMT32E are not
compatible with the Air to Air Heat
Exchanger system. Only ON/OFF
operation is available for RBC-
AMS41E.
For operation details using the
remote controller for the Air to Air
Heat Exchanger NRC-01HE, see
page 10 "6.How to use".
• The central controller can be
used to start / stop the whole
system. It can also be used to
start / stop the Air to Air Heat
Exchanger separately.
* However, setting modifications are
required for separate control.
Contact your dealer for more
information.
• The central controller cannot be
used to control the Ventilation
fan speed or ventilation mode of
the Air to Air Heat Exchanger.
• If the remote controller for the Air
Air to Air
to Air Heat Exchanger NRC-
Heat
01HE has been installed, you
Exchanger
can control the Ventilation fan
speed and ventilation mode of
the Air to Air Heat Exchanger
with the remote controller.
• The remote controller for air
conditioner RBC-AMT32E,
AMS41E cannot be used to
control the Ventilation fan speed
and ventilation mode of the Air to
Air Heat Exchanger.
For operation details using the
remote controller for the Air to Air
Heat Exchanger NRC-01HE, see
page 10 "6.How to use".