36
schwa-medico

Description of the programs

Progr. no. Name
1
Standards: Continuous stimulation with one frequency and one pulse width
1.0
Low frequency
1.1
High frequency
1.2
Gentle low frequency
1.3
Gentle high frequency
2
Han stimulation (according to Prof. Han): These programs run with 2 different phases (different frequen-
cies and pulse widths) which alternate every few seconds.
2.0
Han stimulation 1
2.1
Han stimulation 2
2.2
Han stimulation 2
3
Free Han stimulation: free parameter settings: These programs run with 2 different phases (different
frequencies and pulse widths) which alternate every few seconds.
3.0
Free Han stimulation 1
3.1
Free Han stimulation 2
3.2
Free Han stimulation 3
4
Frequency modulation (FM) - The frequency is automatically modified within a specific range:
Min frequency - Max frequency - Min frequency
The pulse width is constantly adapted depending on the frequency.
4.0
Frequency modulation 1
4.1
Frequency modulation 2
4.2
Frequency modulation 3
5
Pulse width modulation - The program uses a fixed frequency but the pulse width is automatically
modified within a specific range: Min pulse width - Max pulse width - Min pulse width
5.0
Pulse width modulation 1
5.1
Pulse width modulation 2
5.2
Pulse width modulation 3
6
Burst - Burst programs use a high frequency stimulation in a low frequency rhythm: impulse packages of
100 Hz are applied for a fraction of time with pauses between the packages.
6.0
Burst 1
6.1
Burst 2
6.2
Burst 3
Instructions for use - AS SUPER 4 digital
Fixed parameters
2 Hz, 210 µs, 30 min
100 Hz, 120 µs, 30 min
2 Hz, 150 µs, 30 min
80 Hz, 70 µs, 30 min
Alternating 2 Hz, 210 µs, 3 s
Alternating 2 Hz, 210 µs, 4 s
Alternating 2 Hz, 210 µs, 2 s
Alternating
2 Hz, 210 µs, 3 s
100 Hz,
120 µs, 3 s, 30 min
Alternating
2 Hz, 210 µs, 3 s
100 Hz,
120 µs, 3 s, 30 min
Alternating
2 Hz, 210 µs, 3 s
100 Hz,
120 µs, 3 s, 30 min
60 Hz
120 Hz, 120 µs
2 Hz
120 Hz, 210 µs
100 µs in 60 s, 30 min
2 Hz
15 Hz, 210 µs
200 µs in 60 s, 30 min
2 Hz, 100 µs
210 µs in 120 s, 30 min
15 Hz, 100 µs
210 µs in 120 s, 30 min
80 Hz, 60 µs
150 µs in 120 s, 30 min
100 Hz (150 µs) impulses packages for 0.25 s,
then 0.25 s pause (2 Hz), 30 min
100 Hz (150 µs) impulse packages for 0.5 s,
then 0.5 s pause (1 Hz), 30 min
100 Hz (60 µs) impulse packages for 0.25 s,
then 0.25 s pause (2 Hz), 30 min
Free parameters for own settings
1-120 Hz, 50-300 µs, 10-90 min
1-120 Hz, 50-300 µs, 10-90 min
1-120 Hz, 50-300 µs, 10-90 min
1-120 Hz, 50-300 µs, 10-90 min
100 Hz, 120 µs, 3 s, 30 min
100 Hz, 120 µs, 2 s, 30 min
100 Hz, 120 µs, 4 s, 30 min
Alternating
F1: 1-120 Hz, 50-300 µs for 3 s
F2: 1-120 Hz, 50-300 µs for 3 s
10-90 min
Alternating
F1: 1-120 Hz, 50-300 µs for 3 s
F2: 1-120 Hz, 50-300 µs for 3 s
10-90 min
Alternating
F1: 1-120 Hz, 50-300 µs for 3 s
F2: 1-120 Hz, 50-300 µs for 3 s
10-90 min
100 µs in 60 s, 30 min