3. To ensure even and rapid
warm air distribution as well
as lower surface tempera-
tures on the heating unit, we
recommend that you operate
the heater with a running
Trumavent warm air system.
The Trumatic S 3002 and
S 5002 heating systems
(with automatic igniters) can
be fitted subsequently with
a remote ignition indicator
(e – Part no. 30040-65400)
with no trouble at all.
If the Trumatic S 5002
heater is combined with
front case with flame effect
it is not possible to have a
remote ignition indicator.
Room thermostat
An average room tempera-
ture of about 22°C can be
achieved without blower
operation with a thermostat
setting of 3 – 5. For opera-
tion with blower, we recom-
mend a thermostat setting of
4 – 8.
The exact thermostat setting
must be determined in ac-
cordance with the design of
the vehicle and the specific
heating requirements.
The thermostat probe
is underneath the
heater. Please note that the
thermostat will be adversely
affected by cold draughts
from refrigerator vents, gaps
below doors, etc., or by a
deep-piled carpet. Always be
sure to avoid problems of this
kind, otherwise satis factory
temperature control cannot
be guaranteed.
Switching off
Turn the control switch to „0"
(the automatic ignition will
switch off at the same time).
If the unit is not used for a
relatively long period of time,
close off the quick-action
gate valve on the gas pipe
and gas bottle.
Control panel
flame effect
(S 5002 only)
0
b
c
a
a = „Off"
(no flame effect,
no sound)
b = Flame effect
without sound
c = Flame effect
with sound
(only flame effect in
variant without sound
effects)
Switching on
Move control panel switch
to (b) flame effect without
sound or (c) flame effect with
sound.
Servicing
In the event of a fault contact
the Truma Service outlet in
the first instance (see page
37).
Caution: Despite
careful manufacture,
the heating system
may contain sharp-
edged components, and pro-
tective gloves should always
be worn when carrying out
any maintenance or cleaning
work.
The electronics can be
damaged by static dis-
charges. Repairs may only be
carried out by an expert!
Removing
the front case
Pull the front case forward at
the top, lift up the retaining
springs and fold out case
forwards. (If space is limited,
lift the front case upwards
and forwards, lift until the
front case is released, then
remove it.)
Then move the front case
aside so that any connecting
cables (e.g. for the Piezo-
igniter, the warm air fan and
the ignition indicator lamp or
the open fire) do not have to
be disconnected.
I
For assembly, place the front
case on the lower retaining
lugs (l). Guide the operating
bar from below into the han-
dle sleeve and allow the front
case to engage at the top.
S 3002 (P) only: Press the
operating handle into position
from above in such a way
that the arrow points to the
„0" position.
Changing battery on
the auto ignitor
If no ignition sparking can be
heard, or only at intervals of
more than one second (or if
the monitor lamp „e", a spe-
cial accessory, is not flash-
ing), the battery needs to be
replaced.
Replace the battery only if the
heater is switched off. Insert
a new battery before the start
of the heating season! Dis-
pose of old battery properly!
Z ü
n d
a u
t o m
a t
Remove the heater cover,
push the battery compart-
ment cover up and change
the battery. Ensure that the
polarity is correct. Close the
battery compartment again.
Only use temperature re-
sistant (+ 70°C), leakproof
Mignon batteries (LR 6, AA,
AM 3, Part no. 30030-99200),
other batteries could caus
operational faults!
Before scrapping the
auto ignitor, remove bat-
tery and dispose of properly!
Cleaning
(only when the unit
is switched off!)
It is recommended that at
least once a year, before the
start of the heating season,
the dust should be removed
which may have collected on
the heat exchanger, the base-
plate, and the fan wheel of
the Truma vent hot air system.
Clean the fan wheel carefully
with a dusting brush or small
paintbrush.
Cleaning the
front screen
(S 5002, front case
with flame effect)
Clean front screen window
with lukewarm water contain-
ing a neutral cleaning agent.
Use a soft sponge, woollen
cloth or chamois leather.
Never use sharp objects or
solvent to remove stains.
Special instructions
1. When the heater is be-
ing operated with a roof
cowl, particularly when
driving, cowl cover T3
(Part no. 30700-03) must
be used, and must be freely
suspended in the air flow. A
cowl extension AKV (Part no.
30010-20800) must also be
installed if necessary. This
must be secured with a screw.
The camper manufacturer or
heater installer must perform
test drives to determine the
combination of cowl top and
extensions (if required) for
the individual as-delivered
vehicle configurations and
consult Truma if necessary.
Depending on the vehicle
model and the equipment in-
stalled on the roof, cowl top
T1 (Part no. 30700-01) or
T2 (Part no. 30700-02) may
be required.