12.0 Safety distance and placement of the stove

The below mentioned distances are minimum distances to combustible materials, relevant for
this stove. These minimum distances must be respected according to the approval.
At these minimum distances the wall can still become warm,(Up to 80°C). To avoid discolorations,
smelly odor from warm paint, to maximize the heat output, and making the cleaning easier, we
recommend that you keep an distance of 80–100mm, also if the walls around the stove are of
noncombustible materials.
* Please note, that the requirements for the fl ue pipe and chimney systems will be diff erent
from the stoves. The mentioned distances are only valid for the stove.
12.1. Safety distances to fl ammable materials using UNINSULATED fl uepipes*:
Distance to infl ammable wall behind stove: W1
Distance to infl ammable side wall:
Distance by corner placement of 45°:
Installation distances in front of stove:
NOTE
: If the wall W2 (photo 1) is longer than 327mm, the distance to W1 must be extended
accordingly.
Photo 1
12.2. Safety distances to fl ammable materials using INSULATED fl uepipes*:
Distance to infl ammable wall behind stove: W1
Distance to infl ammable side wall:
Distance by corner placement of 45°:
Installation distances in front of stove:
NOTE
: If the wall W2 (photo 1) is longer than 302mm, the distance to W1 must be extended
accordingly.
Photo 1
37
100mm
W2 & W3
200/650mm
W4
225mm
1100mm
75mm
W2 & W3
200/600mm
W4
200mm
1100mm
Photo 1
Photo 1
Photo 2
Photo 2
Photo 1
Photo 1
Photo 2
Photo 2