Herunterladen Inhalt Inhalt Diese Seite drucken

Review; Warranty & Safety; Approved By; Tt70 Serie Has Been Tested And Approved By The Following Standards - TermaTech TT70 Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
If a fault occurs during delivery to the customer or if such fault arises during the warranty period
which is covered by this warranty, TermaTech A/S agree to send a suitable replacement part free
of charge to rectify the fault. Any additional obligation of TermaTech A/S to remedy the fault, for
example in the form of installation of the replacement part does not exist.
In addition the purchaser has, apart from the right to a replacement part, no right to either
direct or indirect damages.
Repairs of faults or replacements of parts on the product does not extend the product or replace-
ment parts warranty period. Neither does a new warranty period begin for the product or for the
replaced part.
Apart from the above warranty rules, the consumer also has those rights which are evident from
the obligatory consumer regulation.

9.5. Review

Any fault or defect must be examined by the dealer who has sold the product.
The purchaser must be able to prove that the product was purchased via the dealer and when it
was bought, in the form of an invoice/receipt. The purchaser must specify the model and produc-
tion number which is stated on the product. If the purchaser wishes to refer to a fault, the dealer
must be informed within 14 days of the fault being detected.
9.6 Warranty & Safety
Any unauthorized changes to the wood-burning stove will be viewed as structural change and
thereby the warranty will be void. Safety is also jeopardized.

10.0 Approved by:

TEKNOLOGICAL INSTITUT, Energy and climate
Renewable Energy and Transport
Kongsvang Allé 29
8000 Aarhus C
www.teknologisk.dk
10.1 TT70 Series has been tested and approved by the following standards:
CE - EN13240 (EU)
DIN+ (Germany)
15A (Austria)
NS3058, 3059 (Norway)
AEA (UK)

11.0 Technical specifications:

Type
Nominal output:
Height:
Width:
Depth:
Weigt approx.:
Width of combustion chamber:
Depth of the combustion chamber: 285mm
Smoke nozzle diameter: 150mm
Average values for testing TT70:
Exhaust gas temperature 251°C
Exhaust gas mass flow 5,3 g/s
Efficiency 78%
Flue draught 12 Pa
36
TT70
5,5kW
1040mm
454mm
454mm
107kg
240-355mm

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis