Revitalising

If after about 90 sec . between 7 .5–10 .5 V are
detected, a 12 V battery is present .
Charging starts with a pulse charge for revitalising .
The voltage display
are reached, the appliance switches to the other
charge steps .
Revitalising is the same for all the 12 V charge
programmes .

Program selection

NOTE
If a battery is detected in the voltage range of
between 3 . 7 –7 . 3 V, the programmes 2–3–4
can not be selected . The charging process takes
place automatically . Depending on the selected
program, the characteristic charge curve is
monitored for voltage, time and temperature .
Included are the diagnostics program, revital-
ising mode and retention charge .
(See principle representation program 3 Fig . C)
Program
max. (V)
1 6 V
7,3 V
14,4 V
2
*
3
14,4 V
*
4
14,7 V
*
6 
GB │ IE │ NI │ CY
flashes . Once 10 .5 V
max. (A)
0,8 A
0,8 A
5,0 A
5,0 A
Program 1 „6 V" (7,3 V/0,8 A)
For charging 6 V batteries with a capacity of less
than 14 Ah .
Press the program selection button
program 1 . The symbol „6 V" is displayed on
the LCD . During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars) . When the battery is fully
charged, the condition display
The flashing stops and the appliance automati-
cally switches to retention charge .
Program 2
„12 V" (14,4 V/0,8 A)
For charging 12 V batteries with a capacity of less
than 14 Ah .
Press the program selection button
program 2 . The symbol
LCD . During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars) . When the battery is fully
charged, the condition display
The flashing stops and the appliance automati-
cally switches to retention charge .
Program 3
„12 V" (14,4 V/5,0 A)
For charging 12 V batteries with a capacity of
between 14 Ah–120 Ah .
Press the program selection button
program 3 . The symbol
LCD . During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars) . When the battery is fully
charged, the condition display
The flashing stops and the appliance automati-
cally switches to retention charge .
Program 4
„12 V" (14,7 V/5,0 A)
For charging 12 V batteries with a capacity of
between 14 Ah–120 Ah under cold conditions or
for charging AGM batteries .
Press the program selection button
program 4 .
, to select
shows 4 bars .
, to select
is displayed on the
shows 4 bars .
, to select
is displayed on the
shows 4 bars .
, to select
ULGD 5.0 A1