Processor unit
7
Setting the processor unit parameters (continued)
7.2

Application parameters

Factory setting
The device is preset ex works. The default settings are
highlighted for the respective parameters.
Some parameters are fixed and cannot be modified:
Multiplexing:
The multiplexing sequence and the dwell time in front of
each antenna are fixed.
The sequence in which the antennas are activated is
always 1-2-3-4-1-2-....
Configuration software
The parameters are configured using the "BIS UHF
Manager" software.
One requirement is that the processor is connected to the
controlling system via the service interface (RS232). The
parameter settings can be overwritten at any time.
The parameters can be saved in an XML file so that they
can be retrieved whenever needed.
Detailed information on "BIS UHF Manager" can
be found in the software's online help system.
1. Start "BIS UHF Manager".
2. Click "Device Settings" and "Parameters..." in the
menu bar.
⇒ The "Settings" window appears.
Only the parameters described in the following
can be modified. The area for configuring
advanced device parameters is password-
protected and can only be accessed by a Balluff
service technician.
16
english
3. Start "BIS UHF Manager".
⇒ If "Connect on startup" was selected in the
"Interface Settings" window (default setting), the
device automatically attempts to establish the last
identified connection.
If the device is able to establish the last known connection,
"BIS connected..." appears in the status bar.
If the device is not able to establish a connection, "BIS not
connected..." appears in the status bar.
The device must then be connected manually:
4. Click "Program Settings" and "Interface" in the menu
bar.
⇒ The "Interface Settings" window opens.
Interface settings for service interface (RS232)
When the program starts, the device automatically
connects if "Connect on startup" was selected
in the "Interface Settings" window (factory setting).
When the "Interface Settings" window is opened, the last
known connection is displayed and the bar above the
"Search" button turns yellow.
1. Click the "Search" button.
⇒ The program searches for connections.
⇒ If the program finds a connection, the connection
settings are displayed and the bar above the
"Search" button turns green.
2. Click the "Connect" button.
⇒ The device is connected.
⇒ If the program does not find a connection, the bar
above the "Search" button turns red.