BIS U-6028-048-1_4-06-ST28
Processor unit
8
Function of the device (continued)
9th example
Read the EPCs of multiple data carriers in front of
the antenna
For configuration with 16 byte buffer size!
With a maximum number of 5, EPC size of 12 bytes
configured, 3 data carriers identified
Command from controller
1.
Process output buffer
(note sequence):
01
Command designator 47
hex
02
Type EPC 00
hex
hex
03
Max. number 05
hex
00
/0F
Set AV bit
hex
hex
3a. Process input buffer:
01
Note number of data carriers
hex
02
Save number of bytes
hex
03
/0E
Copy first EPC 12 bytes
hex
hex
3b. Process output buffer:
00
/0F
Invert TI bit
hex
hex
5a. Process input buffer:
01
...0C
Copy second EPC 12 bytes
hex
hex
0D
/0E
Copy third EPC 2 bytes
hex
hex
5b. Process output buffer:
00
/0F
Invert TI bit
hex
hex
7a. Process input buffer:
01
/0A
Copy third EPC 10 bytes
hex
hex
7b. Process output buffer:
00
/0F
Reset AV bit
hex
hex
www.balluff.com
hex
hex
BIS U-6028 reaction
2.
Process input buffer
(note sequence):
00
/0F
Set AA bit
hex
hex
01
Number of data carriers 03
hex
02
Number of bytes per EPC 0C
hex
03
...0E
First EPC 12 bytes
hex
hex
00
/0F
Set AE bit
hex
hex
4.
Process input buffer:
01...0C
Enter second EPC 12 bytes
hex
0D
/0E
Enter third EPC 2 bytes
hex
hex
00
/0F
Invert TO bit
hex
hex
6.
Process input buffer:
01
...0A
Enter third EPC 10 bytes
hex
hex
00
/0F
Invert TO bit
hex
hex
8.
Process input buffer:
00
/0F
Reset AA and AE bits
hex
hex
hex
hex
english