Processor unit
8
Function of the device (continued)
Command designator 42
hex
data carrier (EPC)
Sub-
Meaning
address
00
1st bit
hex
string
01
Command
03
hex
hex
recognition
...
None
No meaning
Last
2nd bit
If first and second bit strings
byte
string
agree, there is valid data
present.
If execution is successful, the response is passed to the
input buffer in the following format:
Sub-
Meaning
address
00
1st bit
hex
string
01
Data
Number of bytes of the EPC
hex
read
...
Data
Transmission of EPC data that
was read from the data carrier.
... is continued, if necessary, in
further buffer transmissions until
the total number of bytes is
reached.
Last
2nd bit
If first and second bit strings
byte
string
agree, there is valid data
present.
www.balluff.com
or 03
: Read individual
hex
Functional description
: read data carrier (EPC)
Functional description
Command designator 44
hex
data carrier (TID)
Sub-
Meaning
address
00
1st bit
hex
string
01
Command
05
hex
hex
recognition
...
None
No meaning
Last
2nd bit
If first and second bit strings
byte
string
agree, there is valid data
present.
If execution is successful, the response is passed to the
input buffer in the following format:
Sub-
Meaning
address
00
1st bit
hex
string
01
Data
Transmission of TID data that
hex
was read from the data carrier.
...
Data
Transmission of TID data that
was read from the data carrier.
... is continued, if necessary, in
further buffer transmissions until
the total number of bytes is
reached.
Last
2nd bit
If first and second bit strings
byte
string
agree, there is valid data
present.
or 05
: Read individual
hex
Functional description
: read data carrier (TID).
Functional description