3. Technical specifications

Model
Energy efficiency class
Rated capacity / rated current
Chosen capacity / current
Electrical connection
Minimum required cable size
1)
Hot water (l/min)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Type
Heating system
Required spec. water resistance @ 15 °C
Spec. electrical conductivity
Inlet temperature
Flow rate to switch on to max. flow rate
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
VDE class of protection
Noise level test certificate
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013
1) Maximum applicable cable size is 10 mm
2) Flow rate limited to achieve optimum temperature rise
3) Without flow regulator
DCX ELECTRONIC MPS®
18 kW..27 kW (26 A..39 A)
18 kW (26 A)
21 kW (30 A)
3~ / PE 380..415 V AC
4.0 mm
4.0 mm
2
9.2
10.7
6.8
7.9
2
A *
)
24 kW (35 A)
27 kW (39 A)
3~ / PE 400 V
6.0 mm
6.0 mm
2
2
12.3
9.0
0.4 l
Pressure type 1.0 MPa (10 bar)
Bare wire heating system IES®
≥ 1100 Ωcm
≤ 90 mS/m
≤ 30 °C
2.5 – 8.0 l/min
2)
0.2 bar at 2.5 l/min
1.3 bar at 9.0 l/min
35 °C / 38 °C / 42 °C / 48 °C / 55 °C
G ½"
3.7 kg
I
PA­IX 6762/I
IP25
19
DCX 13 ELECTR. MPS®
11 kW..13.5 kW (16 A..20 A)
11.0 kW (16 A) 13.5 kW (20 A)
3~ / PE 400 V AC
AC
1.5 mm
2
2
13.8
5.6
10.2
4.1
2.0 – 5.0 l/min
3)
CLAGE
2.5 mm
2
6.9
5.1
2)