Herunterladen Inhalt Inhalt Diese Seite drucken
Phoenix Contact MCR-FL-D-U-I-2SP-24 Bedienungsanleitung

Phoenix Contact MCR-FL-D-U-I-2SP-24 Bedienungsanleitung

Prozess-steuergerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

M M C C R R - - F F L L - - D D - - U U - - I I - - 2 2 S S P P - - 2 2 4 4
M M C C R R - - F F L L - - D D - - U U - - I I - - 2 2 S S P P - - 2 2 3 3 0 0
P P r r o o z z e e s s s s - - S S t t e e u u e e r r g g e e r r ä ä t t
für Strom-/Spannungssignale,
mit Totalisator und 2 Grenzwerten
P P r r o o c c e e s s s s C C o o n n t t r r o o l l l l e e r r
for Current / Voltage signals,
with Adding Counter
and 2 Limits
C C o o n n t t r r ô ô l l e e u u r r d d e e p p r r o o c c e e s s s s
pour signaux de courant/de tension,
avec totalisateur et 2 valeurs limite
C C o o n n t t r r o o l l a a d d o o r r d d e e p p r r o o c c e e s s o o
para señales de corriente y tensión,
con totalizador y dos valores límite

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Phoenix Contact MCR-FL-D-U-I-2SP-24

  • Seite 1 M M C C R R - - F F L L - - D D - - U U - - I I - - 2 2 S S P P - - 2 2 4 4 M M C C R R - - F F L L - - D D - - U U - - I I - - 2 2 S S P P - - 2 2 3 3 0 0 P P r r o o z z e e s s s s - - S S t t e e u u e e r r g g e e r r ä...
  • Seite 2 Werkeinstellung factory preset réglage usine...
  • Seite 3: Inhaltsverzeichnis

    Sicherheits- und Warnhinweise 5.5.2 Grenzwert 2/Grenzwert-Ausgang 2 ............... 23 Bestimmungsgemäßer Gebrauch ..............4 5.5.2.1 Grenzwert 2 aus-/einschalten ............23 Technische Daten 5.5.2.2 Grenzwert 2 zuordnen ..............23 2.1 Allgemeine Angaben ......................5 5.5.2.3 Mode für Grenzwert-Ausgang 2 wählen ........23 2.2 Elektrische Daten ......................
  • Seite 4: Sicherheits- Und Warnhinweise

    1 Sicherheits- und Warnhinweise 2. Technische Daten 2.1 Allgemeine Angaben Benutzen Sie diese Anzeige nur Anzeige 5-stellige rote 7-Segment LED-Anzeige, – bestimmungsgemäß 14,2 mm hohe Ziffern – in technisch einwandfreiem Anzeigebereich –19999 ... 99999, mit Vornullenunterdrückung Zustand Übersteuerungs- Underflow uuuuu / Overflow ooooo –...
  • Seite 5: Ausgänge

    2.6 Bestellschlüssel Bei AC-Ausführungen Spannungsausgang 10 V DC ±2%, 30 mA 10 ... 30 V DC: 28 64 21 5 MCR-FL-D-U-I-2SP-24 Spannungsausgang 24 V DC ±15%, 50 mA 90 ... 260 V AC: 28 64 22 8 MCR-FL-D-U-I-2SP-230 Bei DC-Ausführungen nur Spannungsausgang 10 V DC ±2%, 30 mA...
  • Seite 6: Einbau

    3. Einbau 4.2 Steuereingänge und Hilfsspannungen (U out ) GND3 (für U 10 Uout +10 V/30 mA 11 Uout +24 V/50 mA nur bei Versorgung mit 90 ... 260 V AC MP-Input "Reset-Grenzwert-Latch/ Display-Hold/Reset Totalisator" 1 2 3 4 5 6 7 8 9 10 11 GND2 (KEY/MPI) Tastenverriegelung "Key"...
  • Seite 7: Parametrieren

    Parametrieren – Grenzwerte Wenn negative Werte zugelassen sind, gilt Wert übernehmen: Taste drücken, bei der höchsten Dekade: Nach „9“ folgt der Wert wird gespeichert. Der nächste Die Parameter müssen vor Inbetriebnah- Es können entweder keiner, einer oder „–“ , danach „–1“ und dann erst „0“. me eingestellt werden.
  • Seite 8: Bereichsgrenzen Ändern

    5.2.3Bereichsgrenzen ändern 5.2.4 Kennlinie ändern Die vorgegebenen Grenzen für die ver- entweder übernommen oder angepasst Menü <–> Auswahl schiedenen Eingangsbereiche können werden. Beispiel: Yes ➱ eingegebene Kennlinie verwenden, Kap. 5.4, Parameter Parameter Möglicher Wertebereich Möglicher Wertebereich 0 .. 10 V –0.500 ...
  • Seite 9: Anzahl Der Stützstellen Eingeben

    Eingangsbereich –10 ... + 10 V 5.3.2 Die erste Stützstelle definieren Menü <–> Auswahl Zuerst wird der Eingangswert in der je- Beispiel: –5,000 weiligen Einheit (z.B. V, mA) für den Be- Stelle wählen ginn der Kennlinie eingestellt. Ziffer einstellen übernehmen Danach wird der Anzeigewert für den Be- Menü...
  • Seite 10: Eingangsschwelle Für Den Totalisator Einstellen

    Totalisatorspeichers findet dann nicht blinkt die Anzeige im 1 Sekunden-Takt. Beispiel 1: entleert und der Summenwert auf 0 ge- Ein leerer Behälter wird mit durchschnitt- mehr statt. Überschreitet der Totalisator- Hinweis: Der Wert des Totalisators bleibt stellt (Reset). lich 10 l/s gefüllt, bis ein Volumen von 2 m wert den Anzeigeumfang von 99999, so auch bei einem Stromausfall gespeichert.
  • Seite 11: Dezimalpunkt Für Totalisatorwert Einstellen

    Beispiel 2: Skalierung einstellen Geschwindigkeit von 180 km/h getestet, Wird ein Reifen 1 Stunde lang bei einer legt er 180 km zurück. Menü <–> Auswahl Anzeige Zahlenwert am Anzahl der unskaliertes Ergebnis aktueller Messwert Eingang des Werte im Totalisator Totalistors 180,0 3 600 648 000,0...
  • Seite 12: Grenzwerte/Grenzwertausgänge

    5.5 Grenzwerte/Grenzwertausgänge 5.5.1.4 Hysterese für Grenzwert 1 Es können kein, ein oder zwei Grenzwerte Hysterese bedeutet hier: Differenz der An- Beachte: aktiv sein. sprechschwellen beim Ein- und Ausschal- Grenzwert und Hysterese beziehen sich ten. Diese Differenz ist so groß zu wählen, immer auf den angezeigten Messwert, dass Schwankungen des aktuellen Mess- nicht auf das Mess-Signal.
  • Seite 13: Latch Auf Grenzwert-Ausgang 1 Rücksetzen

    Einschalthysterese ∆a für Grenzwert 1 einstellen 5.5.1.6 Signalform für Ausgang 1 wählen Menü <–> Auswahl Menü <–> Auswahl Beispiel: 1,0 Stelle wählen Ziffer einstellen Positives Ausgangssingnal Arbeitskontakt ist geschlossen, wenn der übernehmen Messwert > Grenzwert 1 ist Ausschalthysterese ∆b für Grenzwert 1 einstellen Negatives Ausgangssignal Menü...
  • Seite 14: Hysterese Für Grenzwert 2

    5.5.2.4 Hysterese für Grenzwert 2 5.5.2.6 Signalform für Ausgang 2 wählen Einschalthysterese ∆a für Grenzwert 2 einstellen Menü <–> Auswahl Menü <–> Auswahl Positives Ausgangssingnal Stelle wählen und Arbeitskontakt ist geschlossen, wenn der Ziffer einstellen aktuelle Messwert > Grenzwert 2 ist übernehmen Negatives Ausgangssignal Ausschalthysterese ∆b für Grenzwert 2 einstellen...
  • Seite 15: Min-Wert Rücksetzbar

    5.6.2.1 MIN-Wert rücksetzbar 5.8 Defaultwerteinstellung meter weitergeschaltet werden alle Para- Über den Parameter hat der An- Menü <–> Auswahl meter auf den voreingestellten Wert zu- wender die Möglichkeit alle Parameter auf Beispiel: Yes rückgesetzt. Die Programmierung muß voreingestellte Werte zurückzusetzen. Im nicht beendet werden, es kann sofort ein Parameter muß...
  • Seite 16: Parametrierung Überprüfen/Ändern

    5.11 Parametrierung überprüfen/ändern 6.1 Anzeige im Betrieb umschalten Menü <–> Auswahl Durch einmaliges Drücken der Taste P Anzeigefunktion gewechselt. Bestätigt wird für 2 s die Bezeichnung der momen- wird dies durch eine 2 s lange Anzeige der Überprüfung der einzelnen Menüs: tan angewählte Funktion angezeigt.
  • Seite 17: Grenzwerte Im Betrieb Einstellen

    6.2 Grenzwert im Betrieb einstellen 6.4 Rücksetzen des Totalisators Grenzwerte im Betrieb einstellen Beachte: Die Tastenverriegelung „Key“ Rücksetzen ist nur möglich, wenn der MP- Rücksetzen: Befindet sich ein Grenzwert in der Anzei- darf nicht aktiviert sein. Eingang für die Funktion Rücksetzen para- •...
  • Seite 18 Safety instructions and warnings ................. 3 5.5.2 Alarms 2/Output 2 ..................... 23 Use according to the intended purpose ............4 5.5.2.1 Alarm 2 off/on .................. 23 Technical Data 5.5.2.2 Select threshold 2 ................23 2.1 Miscellaneous Data ......................5 5.5.2.3 Select mode for output threshold 2 ..........
  • Seite 19: Safety Instructions And Warnings

    1 Safety instructions and warnings 2. Technical Data Only use this display 2.1 Miscellaneous Data – in a way according to its intended Display 5 digit red LED purpose 14.2 mm high – if its technical condition is perfect Display range –19999 ...
  • Seite 20: Outputs

    2.6 Order Code AC models voltage output 10 V DC ±2%, 30 mA 10 ... 30 V DC: 28 64 21 5 MCR-FL-D-U-I-2SP-24 voltage output 24 V DC ±15%, 50 mA 90 ... 260 V AC: 28 64 22 8 MCR-FL-D-U-I-2SP-230 DC models only voltage output 10 V DC ±2%, 30 mA...
  • Seite 21: Mounting

    3. Mounting 4.2 Control inputs and auxiliary power supply (U out ) GND3 (for U 10 Uout +10 V/30 mA 11 Uout +24 V/50 mA only for power supply 90 ... 260 V AC MP-Input "Reset-Alarm-Latch/ Display-Hold/Reset Totalizer" 1 2 3 4 5 6 7 8 9 10 11 GND2 (KEY/MPI) Keypad lock-out “Key”...
  • Seite 22: Parameter Setup

    Parameter setup – Alarms/outputs Where negative values are permitted, the Enter value: Press the key, the highest digit will switch from “9” to”–” value will be stored. The next menu item The parameters have to be set up before Either none, one or two alarm values can and only then to “0”.
  • Seite 23: Setting The Scaling Slope

    5.2.3Changing the Range Limits 5.2.4 Changing the Scaling Slope The given limits for the input range can be Menu <–> Selection entered as is, or adjusted. Example: Yes ➱ use the scaling slope curve, Chapter 5.4, Parameter Parameter Possible range of values Possible range of values 0 ..
  • Seite 24: Enter The Number Of Scaling Points

    Input range –10 ... + 10 V 5.3.2 Define first Scaling point Menu <–> Selection Firstly set the input value for the start of Example: –5.000 the slope using the respective unit (mA, V) Select digit Set digit press the key to accept Menu <–>...
  • Seite 25: Totalizer Setup

    If the totalizer value exceeds the range Note: In the event of a power failure the Example 1: An empty container is filled at an average emptied and the total value set (reset) to 0. 99999 the display blinks once per second. totalizer value is saved.
  • Seite 26: Setting The Decimal Point For The Totalizer

    Example 2: Setting the scaling If a tyre is tested for 1 hour at a speed of 180 km/h, the total distance travelled is 180 km. Menu <–> Selection Instantaneous Numerical value Number of Unscaled result value display at the values in the totalizer totaizer input...
  • Seite 27: Alarms/Alarm Outputs

    5.5 Alarms/Alarm outputs 5.5.1.4 Alarm 1 Hysteresis One, two or no alarms can be active. Here hysteresis means: The difference in value. thresholds between switching on and Note: switching off. This difference should be Alarm value and hysteresis are always selected large enough to avoid undesired based on the displayed current value and When exceeding...
  • Seite 28: Reset Latch Signal At Output 1

    Set switching on hysteresis ∆a for alarm 1 5.5.1.6 Select Signal Form for Output 1 Menu <–> Selection Menu <–> Selection Example 1.0 Select digit Set digit Positive output signal Output is activated, when the instantaneous press the key to accept the selection value >...
  • Seite 29: Reset Latch Signal At Output 2

    5.5.2.4 Hysteresis for Alarm 2 5.5.2.6 Select signal form for output 2 Set switching on hysteresis ∆a for Alarm 2 Menu <–> Selection Menu <–> Selection Positiv output signal Select digit Output is activated, when the instantaneous Set digit value > limit 1 press the key to accept the selection Negativ output signal...
  • Seite 30: Mains Hum Filter

    5.6.2.1 Reset Minimum value 5.8 Setting Default Values The user has the possibility to set all pa- the keys, then all parameters are reset to Menu <–> Selection rameters back to their default values by their default values. It is not necessary to Example: Yes using the parameter .
  • Seite 31: Operation

    5.10 Check/Alter Parameters 6.1 Changing the Display during Operation Menu <–> Selection Pressing the P key once for 2 sec will the next display function. The new identi- identify the function currently selected. If fication will be displayed for 2 sec to con- Checking the individual menu items within these 2 sec the P key is pressed firm this.
  • Seite 32: Resetting The Min/Max Value

    6.2 Setting the Alarms during Operation 6.4 Resetting the Totalizer When an alarm value is shown in the dis- Note: the “key-lock” should not Resetting is possible only if the MP input Reset: play, its set value can be changed. be enabled.
  • Seite 33 Instructions de sécurité et avertissements 5.5.2 Valeur limite 2/Sortie de valeur limite 2 ............23 Utilisation conforme ................... 4 5.5.2.1 Activation / désactivation de la valeur limite 2 ......23 Caractéristiques techniques générales 5.5.2.2 Affectation de la valeur limite 2 ........... 23 2.1 Informations générales ....................
  • Seite 34: Instructions De Sécurité Et Avertissements

    1 Instructions de sécurité et avertissements 2. Caractéristiques techniques 2.1 Informations génerales N’utiliser ces afficheurs que Affichage Affichage rouge à 5 décades, – de manière conforme à leur LED à 7 segments, hauteur des chiffres 14,2 mm destination Plage d’affichage –19999 ...
  • Seite 35: Sorties

    Sortie de tension 10 V CC±2%, 30 mA uniquement Les alimentations d’énergie auxiliaires sont isolées galvaniquement des entrées, des sor- 10 ... 30 V DC: 28 64 21 5 MCR-FL-D-U-I-2SP-24 ties de valeur limite et de la tension d’alimentation. 90 ... 260 V AC:...
  • Seite 36: Montage

    3. Montage 4.2 Entrées de commande et tensions auxiliaires (U out ) GND3 (pour U 10 Uout +10 V/30 mA 11 Uout +24 V/50 mA, seulement pour alimentation 90 ... 260 V AC Entrée IMP "Reset Latch val. limite/ Display-Hold/RAZ totalisateur" 1 2 3 4 5 6 7 8 9 10 11 GND2 (KEY/MPI) Verrouillage des touches "Key"...
  • Seite 37: Paramétrage

    Paramétrage – Valeurs limite Au cas où des valeurs négatives sont au chiffre suivant Il est possible d’activer une, deux ou au- prévues, le „9“ de la décade la plus Les paramètres doivent être réglés avant cune des valeurs limite. Il faut régler élevée est suivi par „-“, puis „-1“, et seu- Confirmer une valuer : appuyer sur la tou- la mise en service.
  • Seite 38: Modification Des Limites De La Plage

    5.2.3 Modification des limites de la plage 5.2.4 Modification de la courbe de fonctionnement Les limites prédéfinies pour les différentes soit ajustées. Menu <–> Choix plages d’entrée peuvent être soit reprises Exemple : Yes ➱ utiliser la courbe de fonctionnement prédéfinie, chap.
  • Seite 39: Détermination Du Nombre De Points Caractéristiques

    Plage d’entrée –10 ... + 10 V 5.3.2 Définition du premier point caractéristique Menu <–> Choix Définir en premier lieu la valeur d’entrée Exemple : –5,000 dans l’unité correspondante (ex. V, mA) Choisir la décade pour le début de la courbe de fonction- Régler le chiffre nement.
  • Seite 40: Réglage Du Seuil D'entrée Du Totalisateur

    s’additionnent plus dans la mémoire du to- clignote à la vitesse de 1 fois par seconde. Exemple 1 : valeur du totalisateur est remise à zéro. Un récipient vide est rempli à la vitesse talisateur. Si la valeur du totalisateur dépas- Nota : la valeur du totalisateur reste sauve- moyenne de 10 l/s, jusqu’à...
  • Seite 41: Réglage Du Point Décimal Pour Le Totalisateur

    Exemple 2 : Réglage de l’échelle Si un pneu est soumis à un test à 180 km/h pendant une heure, il parcourt une distan- ce de 180 km. Menu <–> Choix Valeur Valeur numérique Nombre Somme interne instantanée à l’entrée du de valeurs au totalisateur affichée...
  • Seite 42: Valeurs Limite / Sorties Des Valeurs Limite

    5.5 Valeurs limite/sorties de valeur limite 5.5.1.4 Hystérésis pour la valeur limite 1 Il est possible d’activer une, deux ou au- Hystérésis signifie ici : différence entre les désirables en sortie. cune de valeurs limite. seuils de réponse pour le déclenchement N.B.: Les valeurs minimum et maximum et et pour l'arrêt.
  • Seite 43: Réinitialisation Du Signal Latch Sur La Sortie De Valeur Limite 1

    Réglage de l’hystérésis de déclenchement ∆a pour la valeur limite 1 5.5.1.6 Choix de la forme du signal pour la sortie de valeur limite1 Menu <–> Choix Menu <–> Choix Exemple : 1,0 Choisir la décade Signal de sortie positif Régler le chiffre Le contact de travail est fermé...
  • Seite 44: Hystérésis Pour La Valeur Limite 2

    5.5.2.4 Hystérésis pour la valeur limite 2 5.5.2.6 Choix de la forme du signal pour la sortie de valeur limite 2 Réglage de l’hystérésis de déclenchement ∆a pour la valeur limite 2 Menu <–> Choix Menu <–> Choix Signal de sortie positif Choisir la décade Le contact de travail est fermé...
  • Seite 45: Réinitialisation De La Valeur Minimale

    5.6.2.1 Réinitialisation de la valeur minimale 5.9 Rétablissement des valeurs de réglage par défaut paramètres sont rétablis à leur valeur pré- Le paramètre permet à l’utilisa- Menu <–> Choix réglée par défaut. Il n’est pas nécessaire teur de rétablir la valeur par défaut pour Exemple : Yes de terminer la programmation, il est possi- tous les paramètres.
  • Seite 46: Vérification/Modification Du Paramétrage

    5.10 Vérification/modification du paramétrage 6.1 Modification de l’affichage pendant le condes pour passer à la fonction d'affi- fonctionnement chage suivante. Ce changement est con- Menu <–> Choix firmé par l’affichage pendant 2 secondes Appuyer une fois sur la touche P pour du nom de la nouvelle fonction active.
  • Seite 47: Réglage Des Valeurs Limite Pendant Le Fonctionnement

    6.2 Réglage des valeurs limite pendant 6.4 Remise à zéro du totalisateur le fonctionnement La remise à zéro n’est possible que si la Remise à zéro: Quand une valeur limite est affichée, il est N.B.: Le verrouillage des touches „KEY“ fonction RAZ a été...
  • Seite 48 Instrucciones de seguridad y de advertencia 5.5.2 Valor límite 2/Salida de valor límite 2 ............23 Empleo normal ....................4 5.5.2.1 Activar o desactivar el valor límite 2 ...........23 Información técnica 5.5.2.2 Asignar el valor límite 2 ..............23 2.1 Datos generales......................... 5 5.5.2.3 Seleccionar el modo para la salida de valor límite 2 ....
  • Seite 49: Instrucciones De Seguridad Y De Advertencia

    1 Instrucciones de Seguridad y de Advertencia 2. Información técnica 2.1 Datos generales Utilizar este indicador sólo: Indicador Indicador LED rojo de 7 segmentos de 5 dígitos – según las instrucciones cifras de una altura de 14, 2 mm. – en condiciones técnicas correctas –...
  • Seite 50: Salidas

    DC 10V ±2%, 30 mA Los suministros de energía auxiliar están separados por aislamiento galvánico de las ent- 10 ... 30 V DC: 28 64 21 5 MCR-FL-D-U-I-2SP-24 radas, las salidas de valores límite y la tensión de alimentación. 90 ... 260 V AC: 28 64 22 8 MCR-FL-D-U-I-2SP-230 Página 6...
  • Seite 51: Montaje

    3. Montaje 4.2 Entradas de control y tensiones auxiliares (U out ) GND3 (para U 10 Uout +10 V/30 mA 11 Uout +24 V/50 mA sólo en alimentación de 90 ... 260 V AC Entrada MP "Reset Latch Valor límite/ Display-Hold/Reset Totalizador"...
  • Seite 52: Parametraje

    Parametraje Si se admiten valores negativos, el final de Guardar el valor: pulsando la tecla la decena será: tras el "9" sigue el (-), de- – Valores límite se registrará el valor. Se visualiza la si- Los parámetros deben ajustarse antes de spués el (-1) y por último el "0".
  • Seite 53: Modificar Los Límites De Escala

    5.2.3Modificar los límites de escala 5.2.4 Modificar la curva característica Menú <–> Selección Los límites indicados para las diferentes se o bien adaptarse. escalas de entrada pueden bien guardar- Ejemplo: Yes ➱ utilizar la curva característica introducida, cap. 5.4, Parámetro: Parámetro Posible escala de valor Posible escala de valor...
  • Seite 54: Introducir El Número De Puntos Básicos

    Escala de entrada –10 ... + 10 V 5.3.2 Definir el primer punto básico Menú <–> Selección En primer lugar se ajustará el valor de Ejemplo: –5,000 entrada en la correspondiente unidad Seleccionar el dígito (por ej. V, mA) para el comienzo de la Ajustar la cifra curva.
  • Seite 55: Ajustar El Umbral De Entrada Para El Totalizador

    Si el valor del totalizador sobrepasa el ta- Indicación: el valor del totalizador perman- Ejemplo 1: vaciará el recipiente y se restablecera el Un recipiente vacío se llenará por término maño del indicador 99999, la indicación ece registrado también en caso de cortes valor sumado a 0 (Reset).
  • Seite 56: Ajustar La Coma Decimal Para El Valor Del Totalizador

    Ejemplo 2: Ajustar el desplazamiento 180 km/h, repondrá un valor de 180 km. Si se realiza una prueba con un neumático durante una hora a una velocidad de Menú <–> Selección Indicación Valor numérico en Número de Resultado no desplazado del valor de entrada valores...
  • Seite 57: Valores Límite/Salidas De Valores Límite

    5.5 Valores límite /Salidas de valores límite 5.5.1.4 Histéresis para el valor límite 1 Pueden estar activos uno, dos o bien ningún valor La histéresis aquí tiene un significado: di- indeseables en la salida límite. ferencia de los niveles de respuesta en la Observación: El valor límite y la histéresis activación y en la desactivación.
  • Seite 58: Reiniciar La Señal Latch En La Salida De Valor Límite 1

    Ajustar la histéresis de activación ∆a para el valor límite 1 5.5.1.6 Seleccionar la forma del señal para la salida 1 Menú <–> Selección Menú <–> Selección Ejemplo: 1,0 Seleccionar dígito Ajustar la cifra Señal de salida positiva El contacto de trabajo está cerrado, cuando el valor de medición Guardar con es >...
  • Seite 59: Histéresis Para El Valor Límite 2

    5.5.2.4 Histéresis para el valor límite 2 5.5.2.6 Seleccionar la forma del señal para la salida 2 Ajustar la histéresis de activación ∆a para el valor límite 2 Menú <–> Selección Menú <–> Selección Señal de salida positiva Seleccionar el dígito El trabajo de contacto está...
  • Seite 60: Valor Mín Restablecible

    5.6.2.1 Valor MÍN restablecible 5.8 Ajustar el valor por defecto al siguiente parámetro, todos los paráme- Mediante el parámetro el usua- Menú <–> Selección tros se restablecen al valor preajustado. rio tiene la posibilidad de restablecer Ejemplo: Yes La programación no tiene que finalizarse, todos los parámetros en los valores prea- puede ejecutarse otro ciclo de programa- justados.
  • Seite 61: Revisar/Modificar El Parametraje

    5.10 Revisar/Modificar el parametraje 6.1 Conmutar indicador en funcionamiento Menú <–> Selección Con una sola pulsación de la tecla P se función del indicador. Para confirmación mostrará durante 2 seg.la denominación aparecerá una indicación con la nueva Revisión de cada Menú: de la función momentánea seleccionada.
  • Seite 62: Ajustar Los Valores Límite En Funcionamiento

    6.2 Ajustar un valor límite en Observación: El bloqueo de teclado „Key“ 6.4 Reiniciar el totalizador funcionamiento no debe estar activado. Ajustar valores límite en funcionamiento. El reinicio sólo es posible si la entrada MP Reinicio: Si aparece un valor límite en el indicador, fue parametrada para la función de reini- •...
  • Seite 63 Phoenix Contact Telefon: 0 52 35 - 3 00 GmbH & Co. KG Telefax: 0 52 35 - 34 12 0 Flachsmarktstraße www.phoenixcontact.com 832825 Blomberg...

Diese Anleitung auch für:

Mcr-fl-d-u-i-2sp-230

Inhaltsverzeichnis