Quick Start Guide – Digital transducer electronics AED-System

Specifications

Type
Accuracy class (with internal calibration)
Number of trade values accord. to EN455501 (R76)
Measuring range
Input sensitivity
Input signal range
Measuring signal resolution, max.
Measuring rate (depending on output format and baud rate)
Cut-off frequency of the digital filter, adjustable (±3 dB)
Bridge excitation voltage U
Measuring signal input; strain gage transducer (Full bridge)
Transducer connection
Input resistance (differential)
Length of transducer cable
Length of interface cable (RS-232)
Calibration signal
Temperature stability of the calibration signal
Linearitäty deviation, related to the full scale value
Temperature influence
on the zero point, related to the full scale value
on the sensitivity related to actual value
Interface
Baud rate, adjustable
Operating voltage (DC)
Current consumption (without load cell)
Nominal temperature range
Service temperature range
Storage temperature range
Dimensions (L x W x H)
Weight, approx.
Degree of protection to DIN 40050 (IEC529)
1)
Excitation from operating voltage
2)
Current consumption ≤ 80 mA + Excitation voltage U
A1195-2.0 de/en/fr/es
1)
(DC)
B
2)
d
µV/e
mV/V
Bit
Hz
Hz
V
MΩ
m
m
mV/V
ppm/°C
%
%/10K
%/10K
baud
V
mA
°C [°F]
°C [°F]
°C [°F]
mm
g
/ Bridge resistance R
B
B
AD101B
0.01
6000
1
±2.0
±3.0
20 (with 1 Hz)
600...4.7
40...0.25
5...10 (= operating voltage)
u 40...4000
6-wire connection
u 15
x 100, calibration incl. cable
x 15 (25-polie Sub-D-female)
2±0.01 %
2.5
±0.01
typ. ±.0.005; max ±0.01
typ. ±0.005; max ±0.01
RS-232
1200...38400
5...10
Residual ripple x 1mV (p.p.)
x 90
–10...+40 [14...104]
–20...+70 [-4...158]
–40...+85 [-40...185]
93 x 53 x 17
40
IP00
23
HBM