6.3. maintenance and inspection

CAUTION!
When cleaning the exterior box of the voltage amplifier, first turn off the power
and unplug the wall power supply. Failure to observe these items may result in a
fire or electrical shock.
Cleaning the exterior box using a firmly wrung-out cloth with soap water. Do not
use alcohols, benzene, paint thinner or other inflammable substances. If
flammable substances come into contact with a electrical component inside the
voltage amplifier, this may result in a fire or electrical shock.

7. instructions for checking the function of the system / quick start

When you open the package, please check to make sure all the necessary parts are
complete (see packing list) and nothing is damaged.
Check the electronics and the actuator for any visible damage:
The top and bottom plate of the actuator (if it does not have another shape)
should be parallel each to each other, without scratches.
If there is any damage to the system please contact our local representative
immediately!
If the packaging material is damaged please confirm this with the shipping
company.
Before you switch on the system, please check:
The main voltage supplied in your country is the same as installed for the wall power
supply, keep the power supply disconnected
Set the operating mode switch to "GENERATOR"
Keep potentiometer in maximum counter clockwise position (left position)
Connect the piezo actuator by using the LEMO connector. Be sure the cables
are connected properly to the electronics.
Connect the wall power supply cord with the amplifier "nano box"
Connect the wall power supply with the mains socket
Depending on the used piezo actuator, you can see or feel a moving of the drive
side, optionally you can increase the moving frequency by carefully turning the
potentiometer clockwise (to the right)
turn to the initial state for usual operation (potentiometer to the left, operating
mode switch to "MODULATION")
The initial function check has been completed.