Safety instructions

Installation, connection, startup and repairs may be carried out by technicians only.
Technicians can specify a suitable attachment and exhaust air conduction for the
extractor hood. The attachment must be suitable for the weight of the extractor hood
and for the load on the wall. Observe the pullout values of the supplied wall plugs. The-
se have the following values depending on the wall:
Highest recommended loads of a single
anchor :
Concrete ≥ C20/25
Brick ≥ Mz 12
Solid calcium silicate brick ≥ KS12
If the wall is made of other uncertain materials, consult a building specialist, e.g. a
structural engineer or an architect to ensure t hat the extractor hood can be installed
securely.
Risk of injury !
The hood structure may have sharp edges caused by the manufacturing process. Wear
protective gloves during installation.
Risk of electric shock !
The mains voltage must correspond with the specifications on the rating plate. The ra-
ting plate is situated near the filters inside the hood. Connect the extractor hood to a
correctly installed earthed socket only. The socket must be easily accessible following
installation so that the extractor hood can be isolated if required. If the extractor hood is
to be permanently connected (e.g. if there is no appropriate socket), it may be connec-
ted to the mains by an electrician only. If the extractor hood is to be permanently
connected, it must be connected to a single electric circuit with disconnector. Switches
with a contact opening of at least 3 mm and all-pole switches, e.g. LS switches and
contactors, are regarded as disconnectors. Before connecting the extractor hood to the
power supply, disconnect the mains circuit(s). Before drilling fixing holes, ensure that
there are no electric cables which could be damaged by the drilling. When preparing
the power supply connection, ensure that the extractor hood can be connected without
difficulty. Observe local regulations.
Exhaust air conduction for exhaust air mode
The exhaust air must not be led into a chimney which is used for exhaust gases from
devices with fuels (e.g. gas). Official regulations for the discharge of exhaust air must
be observed. The exhaust air path must be prepared in such a way that the cooker
hood can easily be connected to it. The exhaust hose must be cooker hood can be
easily connected to it. The exhaust hose must be laid without kinks. If the extractor
hood is operated simultaneously with other room air dependent fireplaces (e.g. wood-,
gas-, oil- or coal-fired appliances) in one room during exhaust air operation, deadly
combustion gases can be returned to the room through a negative pressure. The ope-
rator must therefore ensure an adequate supply of air at all times. The negative pres-
sure in the room must not exceed 4 Pa (0.04mbar). Do not exceed max. duct length of
5m with B-version.
S 8
UX 10x60
0,60 kN
1,00 kN
0,50 kN
0,50 kN
0,55 kN
0,60 kN
EN
S 10
1,10 kN
- - -
- - -
19