Safety instructions

Installation, connection, startup and repairs may be carried out by technicians only.
Technicians can specify a suitable attachment and exhaust air conduction for the
extractor hood. The attachment must be suitable for the weight of the extractor hood
and for the load on the wall. Observe the pullout values of the supplied wall plugs. The-
se have the following values depending on the wall:
Highest recommended loads of a single anchor :
Concrete ≥ C20/25
Brick ≥ Mz 12
Solid calcium silicate brick ≥ KS12
If the wall is made of other uncertain materials, consult a building specialist, e.g. a
structural engineer or an architect to ensure that the extractor hood can be installed
securely.
Risk of injury
The hood structure may have sharp edges caused by the manufacturing process.
Wear protective gloves during installation.
Installation
The appliance may only be installed and connected by an authorised technician obser-
ving all relevant regulations of the electric utility companies and the applicable building
regulations. During installation, observe the relevant instructions !
Damaged appliances may not be put into operation. Defective parts must be replaced
with genuine parts.
Repairs should only be carried out by authorised technical staff.
Risk of electric shock
The mains voltage must correspond with the specifications on the rating plate. The ra-
ting plate is situated near the filters inside the hood. Connect the extractor hood to a
correctly installed earthed socket only. The socket must be easily accessible following
installation so that the extractor hood can be isolated if required. If the extractor hood is
to be permanently connected (e.g. if there is no appropriate socket), it may be connec-
ted to the mains by an electrician only. If the extractor hood is to be permanently
connected, it must be connected to a single electric circuit with disconnector. Switches
with a contact opening of at least 3 mm and all-pole switches, e.g. LS switches and
contactors, are regarded as disconnectors. Before connecting the extractor hood to the
power supply, disconnect the mains circuit(s). Before drilling fixing holes, ensure that
there are no electric cables which could be damaged by the drilling. When preparing
the power supply connection, ensure that the extractor hood can be connected without
difficulty. Observe local regulations.
Solid fuel fireplaces
The cooker hood may only be installed above a fireplace for solid fuels from which the-
re is a risk of fire (e.g. flying sparks) if the fireplace has a closed, non-removable cover.
Ø 8mm dowels:
0,60 KN
0,50 KN
0,55 KN