Maintenance

Maintenance Table
The following details are manufacturer recommendations. Observe
national guidelines, too.
Work to be carried out
Inspection by wearer of device
Cleaning and Disinfection
Visual inspection, function and
leak tests
Replacing the exhalation valve
disc
Replacing the speech diaphragm
Replacing the O-ring of the
speech diaphragm
1) full facepieces in airtight packaging, otherwise every six months.
2) full facepieces in airtight packaging every 2 years.

Cleaning and Disinfecting

The facepiece must be cleaned after every use so that it is clean
before it is used by a different individual or, if individually assigned, as
often as necessary to keep in a sanitary condition. Facepieces that
are issued to more than one user must be cleaned before being worn
by different individuals.
The facepiece must be disinfected after every use to keep it in a san-
itary condition. It is fully in the user's responsibility to make sure that
the facepiece is totally free of contaminants after this treatment.
Never use a facepiece again, that has not been properly disinfected.
In case of doubts dispose of the facepiece in accordance with the
local regulations and use a new one.
The facepiece body must be cleaned thoroughly so that no residues
from skin care products remain on it.
Otherwise the elasticity in the sealing area can be lost and the
facepiece will no longer fit correctly.
Failure to take note of this warning can result in poisoning or death.
Do not use any solvents (e.g. acetone, alcohol) or cleaning agents
containing abrasive particles for cleaning and disinfecting. Only
apply the described procedures and use the clening and disinfect-
ing agents given. Other agents,dosages and exposure times may
damage the product.
Since the use of certain cleaning and disinfecting agents is not
allowed among all countries, Dräger tested and recommends sev-
eral cleaning and disinfecting agents. However, Dräger makes no
representations that such agents comply with or are approved for
use in your specific country's regulations. Make sure to follow the
procedure that is suitable for your country.For further information
please contact Dräger or your local dealer.
For information about suitable cleaning and disinfecting
agents and their specifications refer to document 9100081
on www.draeger.com/IFU
Maximum intervals
X
1)
X
X
2)
X
X
WARNING
CAUTION
NOTICE
Use instructions for NIOSH-approved full facepieces
Cleaning and Disinfecting Procedure
Remove any accessories from the facepiece and clean them sepa-
1)
rately
.
Prepare a cleaning solution consisting of water and a cleaning
agent.
Clean all parts using a soft cloth with cleaning solution.
Rinse all parts thoroughly under running water.
Prepare a disinfecting solution consisting of water and a disinfecting
agent.
Place all parts that need to be disinfected into the disinfectant bath.
Rinse all parts thoroughly under running water.
Dry all parts in the air or in a drying cabinet (max. temperature:
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.
Mount the accessories if necessary.
Alternative Cleaning and Disinfecting Procedure
Remove any accessories from the facepiece and clean them sepa-
2)
rately
.
Prepare a solution consisting of water and combined agent.
X
Immerse the facepiece in the solution. Make sure that all parts are
wetted.
Thoroughly rinse all parts under running water.
X
Dry all parts in the air or in a drying cabinet (max. temperature:
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
X
facepiece in order to remove water.
Mount the accessories if necessary.

Visual Inspection

Check if the full facepiece is complete and functions correctly.
Check the exhalation valve:
Remove the exhalation valve cover from the mask connector
and pull out the valve disc.
The valve disc and seat must be clean and undamaged.
Clean or replace if necessary. Moisten the valve disc with water
before fitting it.
Maintenance tasks
Carry out both a visual inspection and a leak test after any mainte-
nance work.
Replacing the visor
Mask with metal visor frame: Grip the hexagonal nuts and unscrew
the screws.
Mask with plastic visor frame: Unscrew the screws. Pry the visor
frame apart with a screwdriver at the connecting points, then pull it
off to the top and bottom.
Remove the connector clamp, sliding ring and support if necessary.
Detach the old visor from its rubber frame.
Insert a new visor, first in the upper half and then in the lower half
of the rubber frame.
The center marks on the visor must be aligned with the seam on the
facepiece.
Draw the rubber frame over the edge of the visor on the right and
left.
Moisten the outside of the rubber frame and the inside of the visor
frame with soap solution.
Fit first the upper, then the lower visor frame.
Put support between connector clamp and sliding ring if necessary,
clamp it to the bottom visor frame and align it.
Mask with metal visor frame: Screw the screws into the hexagonal
nuts and tighten until the gap between the clamp lobes is between
3 and 0.5 mm.
Mask with plastic visor frame: Insert and tighten the screws.
Replacing a nose cup valve disc
Pull out the old valve disc towards the inside.
Insert the stud of the new disc into the hole from inside, and pull it
towards the visor until the undercut of the stud is visible.
The valve disc should make even contact with the inside surface.
1) Strictly follow the corresponding Instructions for Use.
2) Strictly follow the corresponding Instructions for Use.
29