Explosion protected terminal boxes made of stainless steel type Ex-Cell XL-T
1

Technical data

ATEX type examination certificate:
Marking acc. to 2014/34/EU and standard:
IECEx type examination certificate:
Marking:
*
1)
Depending on the installed components (terminals) and the ambient temperature
Rated voltage:
Rated current:
Permissible service/operating temperature and storage temperature
in original packaging: depending on sealing used:
standard gasket
flat gasket
*
2) The ambient temperature could be reduced with the use of some enclosure accessories ( dependent on the certification of the accessory)
Protection category acc. to IEC/EN 60529:
Insulation class acc. to IEC/EN 61140:
Terminals:
Cable entries:
Test torques:
Cover screws
Mounting screws for flange plates
Enclosure sizes:
BVS 16 ATEX E 115 X
EN 60079-0
IECEx BVS 16.0080 X
IEC60079-0
Ex e IIC T6/T5/T4*
Ex tb IIIC T80°C (T95°C) (T135°C) Db
up to 690 V AC/DC
up to 500 A
(depending on used terminal and connection cross-section and number of conductors)
temperature class T6*
2)
-40 °C
temperature class T4*
2)
-60 °C
2)
temperature class T5*
-60 °C
temperature class T6*
2)
-60° °C
IP66
I
up to max. 240 mm²
see section 6 and 10
4.0 Nm
2.0 Nm
height (A)
smallest
150 mm
biggest
1600 mm
dimensions
see section 10.1
II 2 G
1)
Ex e IIC T6/T5/T4*
Gb
II 2 D
Ex tb IIIC T80°C (T95°C) (T135°C) Db
1)
Gb
to
+40 °C
to
+120 °C
to
+55 °C
to
+40 °C
(catalogue version)
width (B)
150 mm
1200 mm
GB
depth (C)
80 mm
400 mm
9