Pin configurations of connectors (continued)
DC IN terminal (Mini DIN 8-pin, female)
8
5
2
Pin no.
1
NC
2
GND
3
NC
4
NC
5
GND
6
12V
7
NC
8
12V
LENS terminal (Metal 12-pin, female)
1
2
3
4
11
Pin no.
1
NC
2
NC
3
GND
4
NC
5
IRIS CONTROL
6
12V DC 400mA max.
7
IRIS POSITION
8
IRIS AUTO /MANU
9 to 12
NC
CAUTION
Use device whose current consumption is max.
400 mA or less.
7
6
3
4
1
Signal name
10
9
8
7
6
12
5
Signal name
REMOTE terminal (Metal 10-pin, female)
Compatible plug:
HR10A-10P-10P
7
(Hirose Electronics)
10
6
Pin no.
1
2
TRG IN L active
3
NC
4
FLASH OUT L active
5
6
NC
7
NC
8
GND
9
12V output (only when power
is supplied from AC adapter)
10
NC
CAUTION
• Consult your JVC dealer concerning the re-
mote terminal connection.
• Remote cable must use shielded cable.
Outer shield of remote cable must to connect
10-pin connector outer metal shell.
• Do not input the external trigger during the
first 10 seconds after the power is turned ON.
Terminal
I/O
name
2 TRG IN
IN
• 3.3V CMOS
• Schmidt Trigger
• Pull-up to 3.3V at
4.7k Ω
4 FLASH
OUT
• Open collector
8
1
2
9
3
5
4
Signal name
Conditions
• Contact point
recommended
• Maximum rated
voltage: 5.3V
• H level: 2.4 ~ 5.0V
• L level: 0 ~ 0.5V
• Pulse width:
Min. 130 ms
• Maximum rated
current: 150mA
• Maximum rated
voltage: 12V
E9