9. Specifications
9.3 Float
The float is an essential component of the level transmitter, which must be matched to the
medium in terms of density, pressure strength and material resistance.
EN
The floats listed below are interchangeable and can be reordered individually. Further float
models and materials are available on request.
The density and magnet position of floats of the same type vary slightly, so that
readjustment may be necessary.
All floats can also be used with a pressure of -1 bar (vacuum).
Material
Stainless steel
1.4571 (316Ti)
Titanium 3.7035
(grade 2)
Buna (NBR)
The pressure strength can only be ensured for undamaged floats. Even the
smallest and invisible dents, for example when the float falls from the table
onto a stone floor, are sufficient to significantly reduce the pressure strength.
26
Version
Description
V18/42A
Cylinder Ø 18 mm
V27A
Cylinder Ø 27 mm
V29A
Sphere Ø 29 mm
V29A/40
Cylinder Ø 29 mm
V44A
Cylinder Ø 44 mm
V52A
Sphere Ø 52 mm
T29A
Sphere Ø 29 mm
B20A
Cylinder Ø 20 mm
B23A
Cylinder Ø 23 mm
B25A
Cylinder Ø 25 mm
B30A
Cylinder Ø 30 mm
B40A
Cylinder Ø 40 mm
Operating instructions magnetostrictive level transmitter, models FLM-CA, FLM-CM
For guide tube Ø
in mm
6
6
6
12
12
12
6
6
6
6
6
12
Limit density
85 % in kg/m
3
800
700
920
620
720
690
700
940
800
790
680
580