9. Specifications
9.2 Model FLM-CM
Magnetostrictive level transmitter, model FLM-CM
Guide tube
Process connection
Materials
Wetted parts
Connection head
Insertion length
Measurement accuracy
Resolution
Electrical connection
Supply voltage
Output signal
Operating pressure
Operating temperature
Ambient temperature
Ingress protection per EN 60529
Configuration
For further specifications see data sheet LM 20.05 and the order documentation.
Operating instructions magnetostrictive level transmitter, models FLM-CA, FLM-CM
Ø 6 mm (max. 1,000 mm)
Mounting thread downwards
G 1/2 ... G 2
1/2 NPT ... 2 NPT
Other process connections on request
Stainless steel 1.4571 (316Ti)
Stainless steel 1.4305 (303)
100 ... 1,000 mm
±2.5 mm
0.1 mm
Circular connector M12
DC 8 ... 30 V
4 ... 20 mA (NAMUR NE43)
Depending on the float, max. 40 bar
-40 ... +125 °C
-40 ... +85 °C
IP68
Via USB adapter with corresponding software and a
standard computer
Order number: 14361280