12.4.3 Device access locks
Access to the parameters can be controlled with the Device access locks parameter.
In-
Sub
Off-
Access
dex
-
set
Rights
In-
dex
0x0C
1
0
R/W
2
1
R/W
3
2
R/W
4
3
R/W
Description of parameter values
Index name
Device access locks
12.4.4 Profile Characteristics
The Profile Characteristics parameter specifies which DeviceProfileIDs, CommonApplicationProfileIDs and FunctionClassIDs
are supported.
In-
Sub
Off-
Access
dex
-
set
Rights
In-
dex
0x0D
0
0
RO
Description of parameter values
Index name
Profile Characteristics
www.gemu-group.com
Length
Index name
Device access
1 bit
locks
1 bit
1 bit
1 bit
Parameter
Local user interface
Data storage
Local parameteriza-
tion
Local user interface
Length
Index name
Profile
8 bytes
Characteristics
Parameter
Parameter
Parameter (write)
access
Data storage
Local parameteriz-
ation
Local user interface
Values
0
Enable write access
1
Block write access
0
Enable storage of parameter data in the IO-Link master
1
Block storage of parameter data in the IO-Link master
0
Enable local parameterization
1
Block local parameterization
0
Enable local user interface
1
Block local user interface
Parameter
Values
0x8000
Device identification objects
0x8002
Process data mapping
0x8003
Diagnostics
0x8100
External identification
83 / 112
12 Specific data IO-Link (pin 6)
Type
Values
BooleanT
0
1
BooleanT
0
1
BooleanT
0
1
BooleanT
0
1
Description
Type
Values
ArrayT
0x8000
0x8002
0x8003
0x8100
Description
GEMÜ 566