3 Operation

EN
Floor grinding machine DSM 530S / DSM 650S / DSM 800S
Maintenance needs to be conducted accor-
ding to the operation manual.
Do not use high pressure cleaners to clean
the machine!
Do not operate the machine in areas where
there is risk of explosion or where flamma-
ble materials are present.
3 Operation
Injury hazard from parts flung out during
grinding!
Wear protective clothing and protective gog-
gles.
Wear safety shoes!
Wear safety gloves!
Proceed with the greatest care and caution!
Danger of injury from loud noise during grin-
ding operation of the machine!
Always wear hearing protection is required
when the machine is in operation!
High- -voltage electrical current can be fatal!
Do not allow the power line to be run over,
crushed or pulled on!
Risk of injury from dust formation during
grinding work!
Connect an extractor unit to the machine or
feed in water during the grinding process.
Respiratory protection must be worn!

3.1 Starting up the machine

Follow the safety instructions in Chapter 2!
The initial start- -up of the machine may be
carried out only by qualified personnel.
A visual inspection of the machine needs to
be done before starting up the machine.
Particular attention should be paid to dama-
ged or loose components, wearing and fil-
ling levels.
Always use ETX diamond tools or abrasive bonding
for the surface to be machined (e.g. some surfaces
have to be ground wet).
1.
Disconnect the power plug [4, Fig. A] from the
mains.
2.
Check ETX diamond tools for function and con-
dition and replace if necessary.
(
Chapter 4.3 - page 19).
3.
Check the surface to be ground and remove any
protruding objects.
4.
either (dry grinding)
Attach external dust extraction at the con-
nection to the dust extraction [25, Fig. C]
(customer side).
or (wet grinding)
DSM 530S / DSM 650 S:
Check the water level in the tank
[10, Fig. A] and refill if necessary.
DSM 800S:
Connect the external water supply hose to
the water connection [24, Fig. C] (custo-
mer side).
Dust extraction and water supply are provided
by the customer.
5.
Securely hold the guide bar [3, Fig. A] or secure
it against falling and turn the clamping nuts
[21, Fig. E] anticlockwise, until the locking
disks [22, Fig. E] are disengaged.
6.
Adjust the guide bar to the desired working posi-
tion and tighten the clamping nuts clockwise, so
that the locking disks engage.
7.
Place the ETX locater plate with the inserted
diamond tools on the surface to be ground.
8.
Check the dust cover [9, Fig. A/C] for proper
position and function and, if necessary, correct.
There should be a 3 ... 4 mm gap between
the dust cover and the grinding surface.
9.
Check the safety fixtures for completeness
and function before starting up.
17