3 - TRIPPING RELAY ON PRODUCTS WITH RESIDUAL CURRENT DEVICE

CAUTION

3.1 TRIPPING THE RESIDUAL CURRENT DEVICE

The residual current device can be seen in the second part of the following figure. You may
access the residual current device by opening the lock which is placed on the side cover
as shown in the first part of the figure below. Place and push triangle key on the side cover
lock then rotate the key 90 degree counter-clockwise.
Ensure that there is no failure on your vehicle or on the charging plug that may cause a
residual current before resetting the tripped residual current device.
After ensuring that there is no problem on your vehicle or on the charging plug, unplug the
charging cable from the charging station. Then reactivate your charging station by resetting
the switch as shown in the third part of the figure as shown below.
If the problem still occurs, contact an authorized service. If the problem is solved, there
may be some problem with your vehicle or charging cable. Please contact with your vehicle
service.
1

3.2 DC 6mA LEAKAGE CURRENT SENSOR BEHAVIOR

The charging station is equipped with a DC leakage current sensor that reacts a DC leakage
current higher than 6mA.
If the charging station goes to error state due to DC leakage current, charging cable must be
unplugged from vehicle and then from the charging station to reset this error.