installation
Special connections
3-phase connection (3 a.c. 230 V / 50 Hz):
The voltage between the phases and the neutral is 230 V a.c.
Install connecting bridges between the connection points 3-4. Your groups
must be fused with at least 16 A (3x). The connecting power cable must have a
minimum core cross section of 2,5 mm
3 a.c. 230V / 50 Hz
generators left
4
You can use the bridges provided on the connecting block to make the
required interconnections as indicated in the preceding illustrations.
Safety prescriptions
For the appliance to work well, it is important:
That there is sufficient ventilation to allow the hob to cool down, in
accordance with the possibilities specified in this chapter.
The ventilation air drawn in by the hob must not be warmer than 35 °C.
Bear this in mind if the oven is to be built in under the hob.
That the connecting cable hangs freely and is not caught by a drawer.
The worktop should be a minimum of 2.8 cm and a maximum of 5 cm thick.
The worktop is flat.
2
.
generators
right
3
2
1
appliance
internal