Herunterladen Inhalt Inhalt Diese Seite drucken

Pelgrim IDK664 Anleitung Seite 53

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

53
installation
The appliance can be connected in the following ways:
Common connections
2 lives with 2 neutrals connection (2 2N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c. There may be a voltage of
0 V between the phases if they are connected to the same phase in the meter
cupboard but also 400 V if they are connected to 2 different phases. Your
groups must be fused with at least 16 A (2x). The connecting power cable must
have a minimum core cross section of 2,5 mm
2N a.c. 230V / 50 Hz
generators left
4
3 lives with 1 neutral connection (3 1N a.c. 400 V / 50 Hz):
The voltage between the phases and the neutral is 230 V a.c. There is a voltage
of 400 V between the lives. Fit a connecting bridge between the connection
points 3-4. Phase 3 carries no load. Your groups must be fused with at least
16 A (3x). The connecting power cable must have a minimum core cross section
of 2,5 mm
.
2
1N a.c. 400V / 50 Hz
generators left
4
generators
right
3
2
1
appliance
internal
generators
right
3
2
1
.
2
appliance
internal

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Idk332

Inhaltsverzeichnis