Operating display
Fig. 21
5.21 Input setup
Fig.
22
shows all possible settings.
The inputs for level, stop dosing and diaphragm
leakage can be changed from NO (normally open) to
NC (normally closed) function. If changed, the inputs
must be short-circuited in normal operation. The
dosing monitoring input can be changed from "OFF"
to "ON".
Fig. 22
Operating display
For the analog input, one of the following signal
types can be selected:
4-20 mA (default)
20-4 mA
0-20 mA
20-0 mA.
See also section
Use the buttons
for navigation
Operating display
without changes
5.12
Analog.
27