Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Operator Instructions - Lincoln Electric COOLERTIG 3 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für COOLERTIG 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34

Installation and Operator Instructions

Read this entire section before installation or operation of
the machine.
WARNING
ELECTRIC SHOCK can kill.
Do not operate with covers removed.
Do not operate if cables are wet or
immersed in water.
MOVING PARTS can injure.
Moving parts can injure. Never place
fingers into openings of Cooler.
HOT COOLANT can burn skin.
Always be sure coolant is NOT HOT
before servicing the cooler.
Location and Environment
This machine will operate in harsh environments.
However, it is important that simple preventative
measures are followed to assure long life and reliable
operation.
Do not place or operate this machine on a surface with
an incline greater than 15° from horizontal.
Do not use this machine for pipe thawing.
This machine must be located where there is free
circulation of clean air without restrictions for air
movement to and from the air vents. Do not cover the
machine with paper, cloth or rags when switched on.
Dirt and dust that can be drawn into the machine
should be kept to a minimum.
This machine has a protection rating of IP23. Keep it
dry when possible and do not place it on wet ground
or in puddles.
Locate the machine away from radio controlled
machinery.
Normal operation may adversely affect
the operation of nearby radio controlled machinery,
which may result in injury or equipment damage.
Read the section on electromagnetic compatibility in
this manual.
Do not operate in areas with an ambient temperature
higher than 40°C. The ambient air temperature
influences the parameters of cooling. If the ambient
temperature is higher, the cooling system will be less
effective
WARNING
Avoid placing the cooler near areas of extreme heat.
English
Input Supply Connection
The COOLERTIG 3 could be supplied by welding power
source using 9-PIN socket (see Figure 2).
To connect the input supply to the COOLERTIG 3, turn off
the power to the welding power source and disconnect it
from the input supply.
The allowable input voltages is 400V, 50/60Hz. Make sure
that the supply voltage of the unit matches the cooler's
rated voltage.
Do not switch on the welding power source with the cooler
applied if the reservoir was not filled and the torch's/gun's
hoses are disconnected from the cooling unit. The no
observance of this warning may be cause internal
damages at the cooler unit.
6
WARNING
Figure 2.
English

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis