How to connect wiring to the terminal

■ For stranded wiring

(1) Cut the wire end with cutting pliers,
then strip the insulation to expose
the stranded wiring about 10 mm and
tightly twist the wire ends.
(2) Using a Phillips head screwdriver,
remove the terminal screw(s) on the
terminal board.
(3) Using a ring connector fastener or
pliers, securely clamp each stripped
wire end with a ring pressure terminal.
(4) Place the ring pressure terminal,
and replace and tighten the removed
terminal screw using a screwdriver.

■ Examples of shield wires

(1) Remove cable coat not to scratch braided shield.
(2) Unbraid the braided shield carefully and twist the
unbraided shield wires tightly together. Insulate the shield
wires by covering them with an insulation tube or wrapping
insulation tape around them.
(3) Remove coat of signal wire.
(4) Attach ring pressure terminals to the signal wires and the
shield wires insulated in Step (2).

■ Wiring sample

SW1
* S witch (SW1) must
be upper position.
Black
Orange
Internal heater Capacity
Wiring Color
Black
Orange
3kW
×
2kW
×
1kW
○:
connect
: ×
disconnect
Stranded wire
Ring
pressure
terminal
SW1
CN003
L
N
Power Supply cable
14
Special
Screw
washer
Ring pressure
terminal
Terminal board
Wire
Insulation tape
Insulation tape
External Device Ready
1
Demand*
2-way Valve
Water Pump
Room Thermostat
External Device Notice*
AC/DC 24V Input
MINI Seri-Para I/O Board
(+,-)
MINI Seri-Para I/O Board
(R/C Line A)
Wired Remote Controller
Outdoor Unit or Indoor Unit
*1 W hen the heat capacity for Air-to-Water is
insufficient, output signal is sent to the external
device.
*2 N otice can be input from the external device.
When the notice is input, the icon appears on the
wired remote controller.
Wire from No.1 to 4 of terminal block and CN003
Wire from No.5 to 8, 10 to 12 of terminal block
Wire from No.13 to 18 of terminal block
Screw and
Special washer
Ring
pressure
terminal
Wire
Shield mesh
Shield mesh
DC24V 1A
Cable
(2 × 0.5 mm
2
)
DC24V 6mA
Cable
2
(3 × 0.5 mm
2
)
Cable
(4 × 0.5 mm
2
)
Use shielded wiring