How to connect wiring to the terminal

■ For stranded wiring

(1) Cut the wire end with cutting pliers, then strip the insulation
to expose the stranded wiring about 10 mm and tightly
twist the wire ends.
Stranded wire
(2) Using a Phillips head screwdriver, remove the terminal
screw(s) on the terminal board.
(3) Using a ring connector fastener or pliers, securely clamp
each stripped wire end with a ring pressure terminal.
(4) Place the ring pressure terminal, and replace and tighten
the removed terminal screw using a screwdriver.
Special
Screw
washer
Ring pressure
terminal
Terminal board
Wire
■ Wiring samples
Type U2
Functional ground screw
(External Electronic Expansion
Valve Kit and Schedule Timer)
Remote Control Wiring
Inter-unit Control Wiring
Ground terminal fixing for SG
(SG: Shows the ground for the
shielded cable.)
Clamping
Clip
1
Clamper *
(supplied)
*1 Fasten tightly.
Ring
pressure
terminal
Screw and
Special washer
Ring
pressure
terminal
Wire

■ Examples of shield wires

(1) Remove cable coat not to scratch braided shield.
(2) Unbraid the braided shield carefully and twist the
unbraided shield wires tightly together. Insulate the shield
wires by covering them with an insulation tube or wrapping
insulating tape around them.
(3) Remove coat of signal wire.
(4) Attach ring pressure terminals to the signal wires and the
shield wires insulated in Step (2).
16
Insulating tape
Shield mesh
Insulating tape
Shield mesh
Protective ground screw
(External Solenoid Valve Kit for 3WAY)
Earth Wiring
Power Supply
Clamper *
(supplied)