Herunterladen Inhalt Inhalt Diese Seite drucken

Test Run; How To Remove Front Plate; How To Remove Side Cabinet - Panasonic S-80MW1E5 Installationsanleitung

Air-to-water heatpump for refrigerant r410a
Vorschau ausblenden Andere Handbücher für S-80MW1E5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 74

7. TEST RUN

■ Test Run of Water Circuit
Panasonic
Air-to-Water
Heatpump
Indoor Unit

7-1. How to Remove Front Plate

Please follow the steps below to remove the front plate. Before removing the front plate of indoor unit, always switch off all power
supply (i.e. indoor unit power supply, heater power supply and tank unit power supply).
1.
Remove the 2 mounting screws which located at bottom of the front plate and 1 mounting screw at the front of the plate.
2.
Gently pull the lower section of the front plate towards you to remove the front plate from left and right hooks.
3.
Hold the left edge and right edge of front plate to lift up front plate from hooks.
When reinstalling the
front plate, first set the
2 hooks, which located
at the top of front plate,
into the slots at cabinet.
Then carry out above
steps in the reverse
order.

7-2. How to Remove Side Cabinet

Please follow the steps below to remove the side cabinet. Before removing the front plate of indoor unit always switch off all power
supply (i.e. indoor power supply, heater power supply and tank unit power supply).
1.
Perform the steps in "7-1. How to Remove Front Plate".
2.
Remove all the 13 mounting screws on the left, right and top of the side cabinet.
3.
Gently remove the side cabinet by holding both of the handles.
CAUTION
Screws
Fix the left and right hooks
to cabinet slot properly when
reinstalling front plate.
● When external pump is used, be sure
to install it in independent water circuit
and not direct to the Air-to-Water
External
heatpump indoor unit circuit.
Pump
Hook
Lift up
19