Herunterladen Inhalt Inhalt Diese Seite drucken

Rs-232 Interface - Honeywell IDENT-KEY 3 Montage, Anschluss, Anleitung

Vorschau ausblenden Andere Handbücher für IDENT-KEY 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions IK3 Evaluation Unit Conventional
7.9

RS-232 interface

Possible connections:
- PC/laptop:
- Serial printer:
PL5
PL5
PL4
PL4
DB1
DB1
Jumper settings:
For PC/laptop
For ser. printer
*) Depending on type of printer used
Important information for connecting the RS-232 interface:
PC/laptop
Printer
Programming of EU, read out event memory, update firmware
print out programming and event memory
Permanent listing out of event memory
PL3
PL3
PL4: Open
PL4: Closed
PL5: Open
PL2: 1-2
PL2: 2-3
PL4: Open
PL5: Closed
via "Zero modem cable", RxD and TxD crosswise
(e.g. Item no. 026809)
Depending on the printer being used.
Observe the pin assignment of the interface on the printer.
RS-232
RS-232
COM or
USB adapter box
PC/laptop
or
ser. printer
1
1
2
2
PL1
PL1
3
3
PL2
PL2
Normal op.
Bootloader
CTS *)
DSR *)
Baud rate:
19200 Baud
Word length: 8 Bit
Parity:
non
Handshake:
no
RS-232 Pin assignment
1
Free
2
RxD
Receive Data
3
TxD
Transmit Data
4
Free
5
GND Signal Ground
6
DSR
Data Set Ready
7
RTS
Request to Send
8
CTS
Clear to Send
9
Free
45

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ik3

Inhaltsverzeichnis