44
7.8
Bank/person security
Components for security zones (
Carry out all other connections according to Chapter 7.3 to 7.8
U_ext.
(see 7.8)
e.g.
LED
+U_b
Door strike with load current
or
Door strike with no-load current
(Bridge RX5 with 0R, see 7.4)
Control function relay:
For BPS applications, the control function
relay is defined as a "door strike relay for
indoors".
Output "Hold-up alarm" to the central
control unit:
One of the
three
IK2 outputs is used as an
output with the criterion
connected to a programmable input.
Restrictions for IK2-S, see 4.6
Program the central control unit accordingly.
Mounting and Connection Instructions IK3 Evaluation Unit Conventional
Monetary holdings/vault
NCC
Control function relay
NOC
Hold-up indicator
(lights up 1x
approx. 1 sec.)
"Hold-up" a
nd
):
Analogue
inputs
1 0V 2 3
12k1
U_b
DB1
U_b
0V
IK2 outputs
to central control unit