Mounting and Connection Instructions IK3 Evaluation Unit Conventional
Hold-up
Central
control
armed/
unit
disarmed
AC button SE
(if required)
Door strike
Opening contact
Armature contact
Blocking element
Basic functions
m
Arming/disarming
Disarming of monitoring of banks by "trapping" with a 6-digit PIN code at the staff entrance. The
switching device is installed in a lockable housing.
m
Access after disarming
After disarming every authorized person can release the door with their personal PIN.
m
Threat alarm
Every authorized person is allocated their own threat code.
A threat alarm can be triggered at all code keypads of the monitoring by "trapping" system. No
operating functions other than arming and door release are possible with this keypad. When triggered
a "still alarm" is triggered to the rescue services.
The output "Hold-up indicator" is actuated for 1 sec. and the alarm is stored until it is reset.
m
Disarming with threat code
In the event of disarming with a threat code, the zone is disarmed and the door for the triggering pin is
released immediately for 5 sec.
The opening of the staff entrance door (access) is then delayed for the following persons for one minute
(for every access).
Cancel delay time: When threat alarm is reset.
m
Door control to inboard security zone/vaults
Press button TA1 to activate a blocking time of 5 minutes. When the 5 minutes have expired, the
code keypads are enabled for 5 minutes to open the doors to these zones. Within this time, the doors
can be opened with a door open code. After 5 minutes, the code keypads are deactivated again.
Priority function:
When the button TA2 is activated
seconds.
m
Remote unlocking of customer entrance door
The customer entrance door can be permanently enabled or the enabling monitored (controlled
access to the bank) via an OPEN/CLOSE button or switch.
Staff entrance
IK2 alarm output
AC- DO rel.
Ai1
Ai2
BE
inside
the room, the door strike releases the entrance door for 30
Monetary holdings/vault
IK3 EU
RS-485
F
I
1
2
3
4
5
6
Door strike
7
8
9
r
0
3
External reader
Input forced unlocking
CF rel.
RS-485
Ai3
TA1
F
I
1
2
3
4
5
6
7
8
9
r
0
3
Internal reader