Herunterladen Inhalt Inhalt Diese Seite drucken

Led Display - Balluff BMF 415KW-HA W-5-Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BMF 415KW-HA W-5-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BMF 415KW-HA _ _ _ -W-5- _ _ -...
Magnetic Field Sensors
3
Construction and function (continued)
3.2

LED display

Yellow (function indicator)
Red (fault indicator)
Green (power indicator)
Color
Function
Green
Power indicator
Yellow
Function indicator On
Red
Fault indicator
All LEDs
Special fault
(green/yellow/red)
indicator
The assured switching field strength is the required magnetic minimum
1)
field strength over the entire temperature range, measured axially in the
slot base.
Tab. 3-1:
LED display
8
english
LED
State
On
Flashes
(900 ms on : 100 ms off)
Flashes
(250 ms on : 250 ms off)
On
(green and yellow LEDs
are off)
Flashes
(250 ms on : 250 ms off,
green and yellow LEDs
are off)
Flash
(250 ms on : 250 ms off)
Meaning
The sensor is operating normally. The required
operating voltage is available.
IO-Link communication is active.
The switching point has been reached and the
switching conditions are met provided no fault is
detected. The axial magnetic field (measured by the
sensor at the bottom of the slot) is ≥ 6.5 mT and
thereby corresponds to the assured magnetic
switching field strength H
.
1)
a
The switching point has been reached and the output
is switched. The measured magnetic field strength is
however sufficient only for operation under the current
ambient conditions and the current sensor
temperature, and corresponds to the rated switching
field strength H
of typically 6 mT.
n
► Check whether the sensor still detects the set
switching point after a temperature change and
reset the switching point if necessary.
A hardware error was detected. This may be caused
by the following:
– Excessive load current on the switching output (I
+5 %)
– Output driver too hot (T
 ≥ 125 °C)
driver
– Sensor supply voltage too low (U
Fault / communication error on the internal data bus
Error during initiation
load
on L+ < 6.5 V)
B

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis